CEST MRI Processing Pipeline in Pilot Study of Alzheimer's Disease Patients.

Asturias Alexander, Yu Fang Frank, Davenport Elizabeth M, Kelley Brendan J, Dimitrov Ivan E, Keupp Jochen, Vinogradov Elena

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To develop a processing pipeline combining neuroimaging analysis tools with CEST postprocessing and utilize it in a pilot study probing differences between cognitively impaired (CI) Alzheimer's disease (AD) patients and cognitively normal (CN) individuals.

METHODS

Eight subjects (4 biomarker confirmed CI with underlying AD and 4 CN) were scanned on a 3T MRI scanner. The processing pipeline included rigid motion correction and co-registration of the CEST images with the 3D T1w images using Advanced Normalization Tools (ANTs). MTRasym maps at 1 ppm, 2 ppm and 3.5 ppm were generated on a voxel-by-voxel basis. Each subject's 3D T1w images were processed with FreeSurfer to generate brain region specific ROIs, and the MTRasym values were averaged over the generated ROIs. In addition, a 6-pool Lorentzian multi-peak model was fitted to averaged Z-spectrum data per ROI. Between-group (CI vs. CN) CEST effects were evaluated using Mann-Whitney U tests.

RESULTS

Motion correction reduced artifacts and visually improved CEST results. Multiple cortical and white matter ROIs showed differences in MTRasym values between CI and CN groups (p < 0.05). Overall, the mean MTRasym and Lorentzian amplitudes were lower in the CI than in the CN group.

CONCLUSION

Our proposed pipeline enables robust data analysis using either MTRasym or multi-pool Lorentzian quantification approaches. The results suggest feasibility for detecting CEST differences between CI and CN groups in brain regions previously implicated in AD, motivating future validation in larger cohorts.

Для цитирования: Asturias Alexander, Yu Fang Frank, Davenport Elizabeth M, Kelley Brendan J, Dimitrov Ivan E, Keupp Jochen, Vinogradov Elena. CEST MRI Processing Pipeline in Pilot Study of Alzheimer's Disease Patients.. Magnetic resonance in medicine. 2026. DOI: 10.1002/mrm.70240.