MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00280-019-04012-z

Медицинская библиотека · Cancer chemotherapy and pharmacology · 2019

Looking beyond the audiogram in ototoxicity associated with platinum-based chemotherapy.

Baguley David M, Prayuenyong Pattarawadee

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

INTRODUCTION

Ototoxicity associated with platinum-based chemotherapy is highly prevalent and can cause detrimental consequences among cancer survivors.

DISCUSSION: In this article, we highlight important aspects of the evaluation of ototoxicity with the aim to increase awareness of Oncologists in this regard. Standard pure tone audiometry alone is inadequate for this context. Comprehensive and consistent hearing tests should be implemented in a monitoring and surveillance program. High-frequency audiometry (10-16 kHz) is a sensitive tool in the detection of ototoxic hearing loss at onset. In addition to threshold audiometry, measures of speech comprehension (both in quiet and in noise) can add useful information in the evaluation of hearing in real-life situations. Not only hearing loss, but also tinnitus and imbalance are common in patients who receive platinum-based chemotherapy, and can cause debilitating effects upon quality of life in this population. Moreover, self-report measures associated with cochlear and vestibular handicaps can provide valuable information regarding the impact of ototoxicity.

CONCLUSIONS

It is vital to build awareness about the variety and impact of the symptoms of ototoxicity. Comprehensive evaluation of hearing status along with self-reported impact of the cochlear and vestibular handicap should be implemented in a monitoring and surveillance program for appropriate investigation and management.

Для цитирования: Baguley David M, Prayuenyong Pattarawadee. Looking beyond the audiogram in ototoxicity associated with platinum-based chemotherapy.. Cancer chemotherapy and pharmacology. 2019. DOI: 10.1007/s00280-019-04012-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.