Standardized Ultrasound Measurement of Subcutaneous Fat Patterning: High Reliability and Accuracy in Groups Ranging from Lean to Obese.

Störchle Paul, Müller Wolfram, Sengeis Marietta, Ahammer Helmut, Fürhapter-Rieger Alfred, Bachl Norbert, Lackner Sonja, Mörkl Sabrina, Holasek Sandra

СтатьяПеревод пока не подготовлен

Аннотация

A recently standardized ultrasound technique for measuring subcutaneous adipose tissue (SAT) was applied to normal-weight, overweight and obese persons. Eight measurement sites were used: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh and medial calf. Fat compression was avoided. Fat patterning in 38 participants (body mass index: 18.6-40.3 kgm-2; SAT thickness sums from eight sites: 12-245 mm) was evaluated using a software specifically designed for semi-automatic multiple thickness measurements in SAT (sound speed: 1450 m/s) that also quantifies embedded fibrous structures. With respect to ultrasound intra-observer results, the correlation coefficient ρ = 0.999 (p < 0.01), standard error of the estimate = 1.1 mm and 95% of measurements were within ±2.2 mm. For the normal-weight subgroup, the median measurement deviation was 0.43 mm (1.1% of mean thickness), and for the obese/overweight subgroup it was 0.89 mm (0.5%). The eight sites used here are suggested to represent inter-individual differences in SAT patterning. High measurement accuracy and reliability can be obtained in all groups, from lean to overweight and obese, provided that measurers are trained appropriately.

Для цитирования: Störchle Paul, Müller Wolfram, Sengeis Marietta, Ahammer Helmut, Fürhapter-Rieger Alfred, Bachl Norbert, Lackner Sonja, Mörkl Sabrina, Holasek Sandra. Standardized Ultrasound Measurement of Subcutaneous Fat Patterning: High Reliability and Accuracy in Groups Ranging from Lean to Obese.. Ultrasound in medicine & biology. 2016. DOI: 10.1016/j.ultrasmedbio.2016.09.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.