MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajodo.2024.04.003

Медицинская библиотека · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2024

Comparison of alignment efficiency of different sizes of superelastic nickel-titanium archwires in the initial phase of fixed orthodontic treatment: A single-center, double-blind randomized clinical trial.

Tahamtan Shabnam, Hajihosseini Morteza, Sohrabi Aydin

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

This 3-arm parallel, double-blind study aimed to evaluate the alignment efficiency of 3 different diameters of superelastic nickel-titanium (NiTi) archwires during the initial phase of orthodontic treatment.

METHODS

Ninety-three patients with nonextraction treatment in the mandibular arch (using 0.022-in Roth prescription brackets) were randomly allocated into 3 groups: 0.012-in NiTi (group 1), 0.014-in NiTi (group 2), and 0.016-in NiTi (group 3). The alignment change was measured using the modified Little's irregularity index before archwire placement and every 4 weeks. The alignment efficiency of the 3 groups was analyzed.

RESULTS

Ninety patients were analyzed (group 1: n = 29, group 2: n = 31, and group 3: n = 30; overall mean age, 16.6 years). The overall Wald test analysis revealed that wire type was not statistically significant (P = 0.91), whereas time exhibited significance as expected (P <0.001). Furthermore, the interaction between wire type and time was not significant (P = 0.93). The time-adjusted estimated difference between 0.014-in and 0.012-in was -0.49 (95% confidence interval, -2.83 to 1.85; P = 0.68). The time-adjusted estimated difference between 0.016-in and 0.012-in was -0.45 (95% confidence interval, -2.95 to 2.05; P = 0.72). No harm was observed.

CONCLUSIONS

The clinical performance of 3 different sizes of NiTi archwires was similar. In addition, 0.014-in and 0.016-in NiTi archwires demonstrated better performances in aligning any irregularities because of a greater number of wire deformations in the 0.012-in group.

REGISTRATION: IR.TBZMED.REC.1395.1039.

PROTOCOL: The protocol was not published before trial commencement.

FUNDING: None.

Для цитирования: Tahamtan Shabnam, Hajihosseini Morteza, Sohrabi Aydin. Comparison of alignment efficiency of different sizes of superelastic nickel-titanium archwires in the initial phase of fixed orthodontic treatment: A single-center, double-blind randomized clinical trial.. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2024. DOI: 10.1016/j.ajodo.2024.04.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.