MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3233/ch-2011-1459

Медицинская библиотека · Clinical hemorheology and microcirculation · 2011

Contrast-enhanced ultrasonography (CEUS) using early dynamic in microcirculation for localization of pathological parathyroid glands: first-line or complimentary diagnostic modality?

Hornung Matthias, Jung Ernst Michael, Stroszczynski Christian, Schlitt Hans J, Agha Ayman

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Contrast-enhanced ultrasonography (CEUS) represents a new diagnostic tool to localize pathological parathyroid glands. The aim of this study was to differentiate the capability of CEUS as first-line or complimentary modality for the detection of hyperfunctioning parathyroid glands.

METHODS

Sixty patients with pHPT were admitted to the University Hospital Regensburg between 8/2009 and 3/2011. Conventional and contrast-enhanced ultrasonography (CEUS) using a linear probe (6-9 MHz, LOGIQ E9/GE) was performed in all patients preoperatively. The sensitivity of CEUS was analyzed to determine its potential as first line or complimentary diagnostic procedure.

RESULTS

Using CEUS 98.3% of all pathological glands could be detected in the correct quadrant whereas conventional ultrasonography (70%) (p < 0.001) revealed less sensitivity. In all patients CEUS indicated a correct side localization of the hyperfunctioning parathyroid gland. The advantage of CEUS was the detection of the early dynamic on the capillary level immediately after contrast injection. Overall, CEUS permit minimally invasive video-assisted parathyroidectomy in 45 patients. 15 patients required conventional procedure due to concomitant goiter. All patients showed normal calcium and parathyroid hormone serum levels three months after surgery.

CONCLUSIONS

CEUS represents a highly sensitive diagnostic modality for localization of pathologic parathyroid glands in patients with pHPT. Nevertheless, it can only be recommended as first-line diagnostic procedure in specialized clinical centers with experienced investigators.

Для цитирования: Hornung Matthias, Jung Ernst Michael, Stroszczynski Christian, Schlitt Hans J, Agha Ayman. Contrast-enhanced ultrasonography (CEUS) using early dynamic in microcirculation for localization of pathological parathyroid glands: first-line or complimentary diagnostic modality?. Clinical hemorheology and microcirculation. 2011. DOI: 10.3233/ch-2011-1459.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.