Journal of the American Geriatrics Society · 2019
A Practical Two-Stage Frailty Assessment for Older Adults Undergoing Aortic Valve Replacement.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hosler Quinn P, Maltagliati Anthony J, Shi Sandra M, Afilalo Jonathan, Popma Jeffrey J, Khabbaz Kamal R, Laham Roger J, Guibone Kimberly, Kim Dae Hyun
Аннотация
OBJECTIVES: Despite evidence, frailty is not routinely assessed before cardiac surgery. We compared five brief frailty tests for predicting poor outcomes after aortic valve replacement and evaluated a strategy of performing comprehensive geriatric assessment (CGA) in screen-positive patients.
DESIGN: Prospective cohort study.
SETTING: A single academic center.
PARTICIPANTS: Patients undergoing surgical aortic valve replacement (SAVR) (n = 91; mean age = 77.8 y) or transcatheter aortic valve replacement (TAVR) (n = 137; mean age = 84.5 y) from February 2014 to June 2017.
MEASUREMENTS: Brief frailty tests (Fatigue, Resistance, Ambulation, Illness, and Loss of weight [FRAIL] scale; Clinical Frailty Scale; grip strength; gait speed; and chair rise) and a deficit-accumulation frailty index based on CGA (CGA-FI) were measured at baseline. A composite of death or functional decline and severe symptoms at 6 months was assessed.
RESULTS: The outcome occurred in 8.8% (n = 8) after SAVR and 24.8% (n = 34) after TAVR. The chair rise test showed the highest discrimination in the SAVR (C statistic = .76) and TAVR cohorts (C statistic = .63). When the chair rise test was chosen as a screening test (≥17 s for SAVR and ≥23 s for TAVR), the incidence of outcome for screen-negative patients, screen-positive patients with CGA-FI of .34 or lower, and screen-positive patients with CGA-FI higher than .34 were 1.9% (n = 1/54), 5.3% (n = 1/19), and 33.3% (n = 6/18) after SAVR, respectively, and 15.0% (n = 9/60), 14.3% (n = 3/21), and 38.3% (n = 22/56) after TAVR, respectively. Compared with routinely performing CGA, targeting CGA to screen-positive patients would result in 54 fewer CGAs, without compromising sensitivity (routine vs targeted: .75 vs .75; P = 1.00) and specificity (.84 vs .86; P = 1.00) in the SAVR cohort; and 60 fewer CGAs with lower sensitivity (.82 vs.65; P = .03) and higher specificity (.50 vs .67; P < .01) in the TAVR cohort.
CONCLUSIONS: The chair rise test with targeted CGA may be a practical strategy to identify older patients at high risk for mortality and poor recovery after SAVR and TAVR in whom individualized care management should be considered. J Am Geriatr Soc 67:2031-2037, 2019.
DESIGN: Prospective cohort study.
SETTING: A single academic center.
PARTICIPANTS: Patients undergoing surgical aortic valve replacement (SAVR) (n = 91; mean age = 77.8 y) or transcatheter aortic valve replacement (TAVR) (n = 137; mean age = 84.5 y) from February 2014 to June 2017.
MEASUREMENTS: Brief frailty tests (Fatigue, Resistance, Ambulation, Illness, and Loss of weight [FRAIL] scale; Clinical Frailty Scale; grip strength; gait speed; and chair rise) and a deficit-accumulation frailty index based on CGA (CGA-FI) were measured at baseline. A composite of death or functional decline and severe symptoms at 6 months was assessed.
RESULTS: The outcome occurred in 8.8% (n = 8) after SAVR and 24.8% (n = 34) after TAVR. The chair rise test showed the highest discrimination in the SAVR (C statistic = .76) and TAVR cohorts (C statistic = .63). When the chair rise test was chosen as a screening test (≥17 s for SAVR and ≥23 s for TAVR), the incidence of outcome for screen-negative patients, screen-positive patients with CGA-FI of .34 or lower, and screen-positive patients with CGA-FI higher than .34 were 1.9% (n = 1/54), 5.3% (n = 1/19), and 33.3% (n = 6/18) after SAVR, respectively, and 15.0% (n = 9/60), 14.3% (n = 3/21), and 38.3% (n = 22/56) after TAVR, respectively. Compared with routinely performing CGA, targeting CGA to screen-positive patients would result in 54 fewer CGAs, without compromising sensitivity (routine vs targeted: .75 vs .75; P = 1.00) and specificity (.84 vs .86; P = 1.00) in the SAVR cohort; and 60 fewer CGAs with lower sensitivity (.82 vs.65; P = .03) and higher specificity (.50 vs .67; P < .01) in the TAVR cohort.
CONCLUSIONS: The chair rise test with targeted CGA may be a practical strategy to identify older patients at high risk for mortality and poor recovery after SAVR and TAVR in whom individualized care management should be considered. J Am Geriatr Soc 67:2031-2037, 2019.