DOI 10.3390/s22249955

Медицинская библиотека · Sensors (Basel, Switzerland) · 2022

Dual Wavelength Photoplethysmography Framework for Heart Rate Calculation.

Alkhoury Ludvik, Choi JiWon, Chandran Vishnu D, De Carvalho Gabriela B, Pal Saikat, Kam Moshe

СтатьяПеревод пока не подготовлен

Аннотация

The quality of heart rate (HR) measurements extracted from human photoplethysmography (PPG) signals are known to deteriorate under appreciable human motion. Auxiliary signals, such as accelerometer readings, are usually employed to detect and suppress motion artifacts. A 2019 study by Yifan Zhang and his coinvestigatorsused the noise components extracted from an infrared PPG signal to denoise a green PPG signal from which HR was extracted. Until now, this approach was only tested on "micro-motion" such as finger tapping. In this study, we extend this technique to allow accurate calculation of HR under high-intensity full-body repetitive "macro-motion". Our Dual Wavelength (DWL) framework was tested on PPG data collected from 14 human participants while running on a treadmill. The DWL method showed the following attributes: (1) it performed well under high-intensity full-body repetitive "macro-motion", exhibiting high accuracy in the presence of motion artifacts (as compared to the leading accelerometer-dependent HR calculation techniques TROIKA and JOSS); (2) it used only PPG signals; auxiliary signals such as accelerometer signals were not needed; and (3) it was computationally efficient, hence implementable in wearable devices. DWL yielded a Mean Absolute Error (MAE) of 1.22|0.57 BPM, Mean Absolute Error Percentage (MAEP) of 0.95|0.38%, and performance index (PI) (which is the frequency, in percent, of obtaining an HR estimate that is within ±5 BPM of the HR ground truth) of 95.88|4.9%. Moreover, DWL yielded a short computation period of 3.0|0.3 s to process a 360-second-long run.

Для цитирования: Alkhoury Ludvik, Choi JiWon, Chandran Vishnu D, De Carvalho Gabriela B, Pal Saikat, Kam Moshe. Dual Wavelength Photoplethysmography Framework for Heart Rate Calculation.. Sensors (Basel, Switzerland). 2022. DOI: 10.3390/s22249955.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.