Absolute quantification (ml blood/sec ∗ mm2 tissue) of normal vs. diabetic foot skin microvascular blood perfusion: Feasibility of FM-PPG measurements under clinical conditions.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАVideo-Audio MediaНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Flower R W, Mirza Z, Thom S R
Аннотация
Fluorescence-mediated photoplethysmography (FM-PPG) is the first routine clinical methodology by which to quantifiably measure tissue blood perfusion in absolute terms (mL blood/sec ∗ mm2 tissue). The FM-PPG methodology has been described in detail previously in this journal (MVR 114, 2017, 92-100), along with initial proof-of-concept measurements of blood perfusion in both ocular and forearm skin tissues. The motivation for the current study was to investigate whether FM-PPG can be used readily and routinely under realistic clinical conditions. The vehicle for doing this was to measure medial foot capillary blood flow, i.e., tissue perfusion, in 7 normal subjects, mean = 6.76 ± 2.29 E-005 mL/(sec ∙ mm2), and lesion-free areas of 8 type-2 diabetic patients with skin ulceration, mean = 4.67 + 3.15 E-005 mL/(sec ∙ mm2). Thus, perfusion in the diabetics was found to be moderately lower than that in the normal control subjects. Earlier skin perfusion measurements in medial forearms of 4 normal subjects, mean = 2.64 + 0.22 E-005 mL/(sec ∙ mm2), were lower than both the normal and diabetic foot perfusion measurements. Variability in the heartbeat-to-heartbeat blood perfusion pulses in the skin capillaries, defined as the ratio of the standard deviation among beat-to-beat pulses divided by the mean perfusion of those pulses, was determined for each subject. Average variability in foot skin was 21% in the diabetic population, versus 16% for normal subjects; and it was 18% in forearm skin. We conclude that absolute quantitative FM-PPG measurement of skin blood perfusion at the level of nutritive capillaries is feasible routinely under clinical conditions, allowing for quantitative measurement of skin tissue blood perfusion in absolute terms.
Предметные рубрики MeSH
Blood Flow VelocityCapillariesCase-Control StudiesDiabetic FootFeasibility StudiesFluorescent DyesForearmHumansImage Processing, Computer-AssistedIndocyanine GreenMicrocirculationPerfusion ImagingPhotoplethysmographyPredictive Value of TestsRegional Blood FlowReproducibility of ResultsSkinTime Factors