Clinical chemistry and laboratory medicine · 2015
Total folate and 5-methyltetrahydrofolate in the cerebrospinal fluid of children: correlation and reference values.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Akiyama Tomoyuki, Tada Hiroko, Shiokawa Tsugumi, Kobayashi Katsuhiro, Yoshinaga Harumi
Аннотация
BACKGROUND: Cerebral folate deficiency (CFD) may be underdiagnosed, as it manifests with various non-specific neurological symptoms. The diagnosis of CFD requires a determination of 5-methyltetrahydrofolate (5MTHF) in the cerebrospinal fluid (CSF), which is available in a limited number of specialized laboratories. In clinical biochemistry laboratories, total folate (TF) determination in serum or plasma is routinely performed by automated analyzers. The aim of this study is to determine whether the automated assay of CSF TF is a helpful screening tool for CFD.
METHODS: We analyzed CSF samples collected from 73 pediatric patients. We measured CSF TF, serum TF, and CSF 5MTHF in 73, 70, and 48 patients, respectively. The assay of 5MTHF was conducted by a newly developed system utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS). We investigated the correlation between TF and 5MTHF in the CSF.
RESULTS: There was a strong positive correlation between CSF TF and 5MTHF (ρ=0.930, p<0.0001, n=48). Age was negatively correlated with CSF TF (ρ=-0.557, p<0.0001, n=51), serum TF (ρ=-0.457, p=0.0008, n=51), and CSF 5MTHF (ρ=-0.387, p=0.0263, n=33), but not with the CSF/serum TF ratio.
CONCLUSIONS: The automated assay of CSF TF is helpful to estimate CSF 5MTHF. The CSF TF assay may have a significant impact on the early diagnosis of CFD, because clinicians have better access to it than the 5MTHF assay.
METHODS: We analyzed CSF samples collected from 73 pediatric patients. We measured CSF TF, serum TF, and CSF 5MTHF in 73, 70, and 48 patients, respectively. The assay of 5MTHF was conducted by a newly developed system utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS). We investigated the correlation between TF and 5MTHF in the CSF.
RESULTS: There was a strong positive correlation between CSF TF and 5MTHF (ρ=0.930, p<0.0001, n=48). Age was negatively correlated with CSF TF (ρ=-0.557, p<0.0001, n=51), serum TF (ρ=-0.457, p=0.0008, n=51), and CSF 5MTHF (ρ=-0.387, p=0.0263, n=33), but not with the CSF/serum TF ratio.
CONCLUSIONS: The automated assay of CSF TF is helpful to estimate CSF 5MTHF. The CSF TF assay may have a significant impact on the early diagnosis of CFD, because clinicians have better access to it than the 5MTHF assay.