Медицинская библиотека · Korean journal of radiology · 2019

Combination of Magnetic Resonance Spectroscopy and ¹¹C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma.

Kudulaiti Nijiati, Qiu Tianming, Lu Junfeng, Zhang Huiwei, Zhang Zhengwei, Guan Yihui, Zhuang Dongxiao, Wu Jinsong

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate whether the combination of magnetic resonance spectroscopy (MRS) and ¹¹C-methionine positron emission tomography (¹¹C-MET PET) could increase accurate diagnostic sensitivity for non-enhancing supratentorial gliomas.

MATERIALS AND

METHODS

Between February 2012 and December 2017, 109 patients with non-enhanced supratentorial lesions on contrast-enhanced MRI were enrolled. Each patient underwent MRS and ¹¹C-MET PET before treatment. A lesion was considered to be a glioma when either the MRS or ¹¹C-MET PET results reached the diagnostic threshold. The radiological diagnosis was compared with the pathological diagnosis or medical diagnostic criteria.

RESULTS

The sensitivity and specificity were 60.0% and 50.0% for MRS and 75.8% and 50.0% for ¹¹C-MET PET, respectively. Upon combining the two modalities, the sensitivity and specificity of the imaging-based diagnosis prior to surgery reached 89.5% and 42.9%, respectively. Statistically significant differences in the sensitivities were observed between the combined and individual approaches (MRS alone, 89.5% vs. 60.0%, p < 0.001; ¹¹C-MET PET alone, 89.5% vs. 75.8%, p = 0.001). However, no significant differences in specificity were observed between the combined and individual modalities.

CONCLUSION

The combination of MRS and ¹¹C-MET PET findings significantly increases accurate diagnostic sensitivity for non-enhancing supratentorial gliomas without significantly lowering the specificity. This finding suggests the potential of the combined MRS and ¹¹C-MET PET approach in clinical applications.

Для цитирования: Kudulaiti Nijiati, Qiu Tianming, Lu Junfeng, Zhang Huiwei, Zhang Zhengwei, Guan Yihui, Zhuang Dongxiao, Wu Jinsong. Combination of Magnetic Resonance Spectroscopy and ¹¹C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma.. Korean journal of radiology. 2019. DOI: 10.3348/kjr.2018.0690.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.