Endocrinologia, diabetes y nutricion · 2022
Impact on variables of severe hypoglycaemia and healthcare costs of the use of the FreeStyle system in paediatric population with type 1 diabetes mellitus.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Leiva-Gea Isabel, Porcel Chacón Rocío, Ariza Jiménez Ana Belén, Mora Loro María, Tapia-Ceballos Leopoldo, Jiménez-Hinojosa Jose, Gómez Perea Ana, López Siguero Juan Pedro
Аннотация
INTRODUCTION: Analysis of the impact on severe hypoglycaemia and direct costs of the introduction of the FreeStyle Libre sensor in paediatric population with type 1 Diabetes Mellitus.
MATERIAL AND METHODS: Ambispective single-centre study to assess the impact on severe hypoglycaemia and direct costs, focusing on consumption of materials, in paediatric population with type 1 Diabetes Mellitus before and after introduction of the FreeStyle Libre 1 sensor.
RESULTS: A significant decrease was found in episodes of severe hypoglycaemia, with 4.2 episodes of severe hypoglycaemia per 100 patients under follow-up versus 0.25 episodes per 100 patients a year after introduction of the system. This represents a cost difference for severe hypoglycaemia, estimated at €6559.52 before introduction and €409.97 after introduction of the FreeStyle Libre sensor. We found a decrease in the daily consumption of capillary blood glucose strips, which translates as a decrease in the cost of materials and helps mitigate the cost of the sensor. The cost in materials for the patient with FreeStyle Libre was €185.13 per patient and year higher than conventional control with capillary blood glucose strips.
MATERIAL AND METHODS: Ambispective single-centre study to assess the impact on severe hypoglycaemia and direct costs, focusing on consumption of materials, in paediatric population with type 1 Diabetes Mellitus before and after introduction of the FreeStyle Libre 1 sensor.
RESULTS: A significant decrease was found in episodes of severe hypoglycaemia, with 4.2 episodes of severe hypoglycaemia per 100 patients under follow-up versus 0.25 episodes per 100 patients a year after introduction of the system. This represents a cost difference for severe hypoglycaemia, estimated at €6559.52 before introduction and €409.97 after introduction of the FreeStyle Libre sensor. We found a decrease in the daily consumption of capillary blood glucose strips, which translates as a decrease in the cost of materials and helps mitigate the cost of the sensor. The cost in materials for the patient with FreeStyle Libre was €185.13 per patient and year higher than conventional control with capillary blood glucose strips.