MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-020-01076-3

Медицинская библиотека · Japanese journal of radiology · 2021

3D fat-suppressed T1-weighted volume isotropic turbo spin-echo acquisition (VISTA) imaging for the evaluation of the ectopic posterior pituitary gland.

Azuma Minako, Kadota Yoshihito, Matsuyama Misayo, Moritake Hiroshi, Hirai Toshinori

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We evaluated the usefulness of fat-suppressed three-dimensional T1-weighted volume isotropic turbo spin-echo acquisition (FS 3D T1W-VISTA) imaging for the evaluation of the ectopic posterior pituitary gland (EPPG).

MATERIALS AND

METHODS

This retrospective study included 9 patients with EPPG due to causes other than tumor. All underwent sagittal two-dimensional (2D) T1W-, FS 3D T1W-VISTA- (VISTA), and 3D T2W-driven equilibrium radiofrequency reset pulse (DRIVE) imaging. Two radiologists independently reviewed the 2D T1W- and VISTA images for their image quality and for visualization of the EPPG and of pituitary stalk transection. DRIVE findings were used as the reference standard for pituitary stalk transection. Interobserver and intermodality agreements were evaluated with the kappa (κ) coefficient. The mean grade assigned to the 2D T1W- and the VISTA imaging technique for visualization of the EPPG was assessed by the Mann-Whitney U test.

RESULTS

Interobserver agreement for visualization of the EPPG on 2D T1W- and VISTA images was excellent (κ = 0.82 and κ = 1.00, respectively). The mean grade for EPPG visualization was significantly higher for VISTA- than 2D T1W images (p = 0.0039).

CONCLUSION

FS 3D T1W-VISTA imaging is useful for the evaluation of EPPG. Conventional MRI yields insufficient information for the evaluation of the ectopic posterior pituitary gland (EPPG). The visualization of the EPPG was significantly higher for fat-suppressed three-dimensional T1-weighted volume isotropic turbo spin-echo acquisition (FS 3D T1W-VISTA) than 2D T1W images. FS 3D T1W-VISTA imaging is useful for the evaluation of the EPPG.

Для цитирования: Azuma Minako, Kadota Yoshihito, Matsuyama Misayo, Moritake Hiroshi, Hirai Toshinori. 3D fat-suppressed T1-weighted volume isotropic turbo spin-echo acquisition (VISTA) imaging for the evaluation of the ectopic posterior pituitary gland.. Japanese journal of radiology. 2021. DOI: 10.1007/s11604-020-01076-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.