DOI 10.1055/s-2007-1003157

Медицинская библиотека · Ultraschall in der Medizin (Stuttgart, Germany : 1980) · 1996

[Screening study of the thyroid gland within the scope of color-coded duplex ultrasound of brain-supplying arteries].

Rommel O, Tegenthoff M

СтатьяПеревод пока не подготовлен

Аннотация

AIM: We undertook this study to establish whether thyroid diseases influence colour-coded Duplex sonography of cerebral arteries and whether colour-coded Duplex sonography is superior to B-mode sonography in detecting pathological changes of the thyroid.

METHOD: In 154 patients the thyroid gland as well as the cerebral arteries were examined by colour-coded Duplex sonography.

RESULTS

In 13% of the examined carotid arteries, stenosis or occlusion was detected. Thyroid diseases were found in 21% of the examined patients. In patients with a goitre, carotid arteries were often severely displaced and thyroid vessels exhibited a low resistance waveform, easily to be confused with cerebral arteries. Colour-coded Duplex sonography provides useful information on thyroid vascularisation: however, differentiation between different types of thyroid nodules seems impossible.

CONCLUSION

Investigation of the thyroid gland during colour-coded Duplex sonography of neck vessels is easy to perform. It is not time-consuming and may yield useful additional information that may help to explain the patient's complaints.

Для цитирования: Rommel O, Tegenthoff M. [Screening study of the thyroid gland within the scope of color-coded duplex ultrasound of brain-supplying arteries].. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 1996. DOI: 10.1055/s-2007-1003157.