MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000002547

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2025

Design Parametrization of Central Venous Catheters for Pediatric Dialysis: Supporting the Quest for the Most Influential Features.

Bruno Claudia, Shroff Rukshana, Schievano Silvia, Capelli Claudio

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

Pediatric hemodialysis is a life-saving treatment for children with chronic kidney diseases. Central venous catheters (CVCs) are the most commonly used vascular access, despite being commonly subject to complications leading to inadequate hemodialysis and catheter replacement. The available CVCs feature various design elements reflecting ongoing efforts to achieve optimal performance. Computational fluid dynamics (CFD) can contribute to analyze the flow dynamics within the CVCs. The aim of this study is to investigate the design parameters that most influence the flow performance of CVCs. A design of experiment (DOE) was set up to assess the CFD of two CVC models of 6.5F and 8F size. Blood flow rates, shear stress, residence time, and platelet lysis index were evaluated. The results showed how the proximal side holes were the most influential geometrical features, influencing both the flow rates ( r > 0.64) and the shear stress of the CVCs (| r | > 0.5). At increased flow rate, the side holes were found to be competing with the tip in terms, especially, of residence time inside the CVC. The findings of this DOE show how CFD can contribute to understand the influence of design parameters and potentially guide the development of optimized pediatric-specific CVC models.

Для цитирования: Bruno Claudia, Shroff Rukshana, Schievano Silvia, Capelli Claudio. Design Parametrization of Central Venous Catheters for Pediatric Dialysis: Supporting the Quest for the Most Influential Features.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2025. DOI: 10.1097/mat.0000000000002547.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.