Relative acidic compartment volume as a lysosomal storage disorder-associated biomarker.
СтатьяПоддержка NIH: внешняя программаResearch Support, N.I.H., IntramuralПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
te Vruchte Danielle, Speak Anneliese O, Wallom Kerri L, Al Eisa Nada, Smith David A, Hendriksz Christian J, Simmons Louise, Lachmann Robin H, Cousins Alison, Hartung Ralf, Mengel Eugen, Runz Heiko, Beck Michael, Amraoui Yasmina, Imrie Jackie, Jacklin Elizabeth, Riddick Kate, Yanjanin Nicole M, Wassif Christopher A, Rolfs Arndt, Rimmele Florian, Wright Naomi, Taylor Clare, Ramaswami Uma, Cox Timothy M, Hastings Caroline, Jiang Xuntian, Sidhu Rohini, Ory Daniel S, Arias Begona, Jeyakumar Mylvaganam, Sillence Daniel J, Wraith James E, Porter Forbes D, Cortina-Borja Mario, Platt Frances M
Аннотация
Lysosomal storage disorders (LSDs) occur at a frequency of 1 in every 5,000 live births and are a common cause of pediatric neurodegenerative disease. The relatively small number of patients with LSDs and lack of validated biomarkers are substantial challenges for clinical trial design. Here, we evaluated the use of a commercially available fluorescent probe, Lysotracker, that can be used to measure the relative acidic compartment volume of circulating B cells as a potentially universal biomarker for LSDs. We validated this metric in a mouse model of the LSD Niemann-Pick type C1 disease (NPC1) and in a prospective 5-year international study of NPC patients. Pediatric NPC subjects had elevated acidic compartment volume that correlated with age-adjusted clinical severity and was reduced in response to therapy with miglustat, a European Medicines Agency–approved drug that has been shown to reduce NPC1-associated neuropathology. Measurement of relative acidic compartment volume was also useful for monitoring therapeutic responses of an NPC2 patient after bone marrow transplantation. Furthermore, this metric identified a potential adverse event in NPC1 patients receiving i.v. cyclodextrin therapy. Our data indicate that relative acidic compartment volume may be a useful biomarker to aid diagnosis, clinical monitoring, and evaluation of therapeutic responses in patients with lysosomal disorders.