Patch testing with formaldehyde 2.0% in parallel with 1.0% by the Swedish contact dermatitis research group.

Isaksson Marléne, Bråred-Christensson Johanna, Engfeldt Malin, Lindberg Magnus, Matura Mihaly, Möller Halvor, Ryberg Kristina, Stenberg Berndt, Svedman Cecilia, Bruze Magnus, Swedish Contact Dermatitis Research Group

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

In a multicentre study consecutively patch-tested dermatitis patients were tested simultaneously with 1.0% and 2.0% (w/v) formaldehyde in aqua applied with a micropipette (15 µl) to the filter paper disc in Finn Chambers (0.30 mg/cm(2) and 0.60 mg/cm(2), respectively). A total of 2,122 dermatitis patients were patch-tested. In all, 77 (3.6%) patients reacted positively to formaldehyde; 37 reacted only to 2.0%, 35 reacted to both concentrations and 5 patients reacted only to 1.0%. Significantly more patients were thus diagnosed with contact allergy to formaldehyde with 2.0% compared to 1.0% (p < 0.001) without causing more irritant reactions. The detected number of isolated allergic reactions to the 2 formaldehyde-releasers in the Swedish baseline series and not to formaldehyde itself raises the question whether quaternium-15 1.0% and diazolidinyl urea 2.0% should be present in the Swedish baseline series.

Для цитирования: Isaksson Marléne, Bråred-Christensson Johanna, Engfeldt Malin, Lindberg Magnus, Matura Mihaly, Möller Halvor, Ryberg Kristina, Stenberg Berndt, Svedman Cecilia, Bruze Magnus, Swedish Contact Dermatitis Research Group. Patch testing with formaldehyde 2.0% in parallel with 1.0% by the Swedish contact dermatitis research group.. Acta dermato-venereologica. 2014. DOI: 10.2340/00015555-1748.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.