MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neuroimage.2009.06.003

Медицинская библиотека · NeuroImage · 2009

Automated quantification of caudate atrophy by local registration of serial MRI: evaluation and application in Huntington's disease.

Hobbs Nicola Z, Henley Susie M D, Wild Edward J, Leung Kelvin K, Frost Chris, Barker Roger A, Scahill Rachael I, Barnes Josephine, Tabrizi Sarah J, Fox Nick C

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Caudate atrophy rate measured from serial MRI is proposed as a biomarker of HD progression that may be of use in assessing putative disease-modifying agents. Manual measurement techniques are the most widely applied but are time-consuming. We describe and evaluate an automated technique based on a local registration and boundary shift integral (BSI) approach at the caudate-CSF and caudate-white matter boundaries; caudate boundary shift integral (CBSI).

METHODS

Two-year caudate volume change was measured in controls, premanifest HD and early HD using the CBSI and compared with a detailed manual measure in terms of 1) raw caudate volume change, 2) group differentiation, 3) associations with clinical variables and 4) rater requirements. CBSI additivity was assessed by comparing measurements over a single scan pair (baseline-->2 years), with the sum of measurements from two scan pairs (baseline-->1 year-->2 years).

RESULTS

Techniques produced comparable caudate volume change measurements, although CBSI under-reported by 0.04 ml relative to manual. Both techniques distinguished controls, premanifest and early HD with a stepwise increase in rates across groups. Higher rates (CBSI and manual) were associated with increased proximity to estimated disease onset but not clinical change scores. CBSI reduced rater requirements by 2/3 (2 h per subject) relative to manual for this three time-point investigation. CBSI measurements over one scan pair showed good agreement with the sum of measurements from two scan pairs.

CONCLUSIONS

CBSI results were comparable to a manual measure but with reduced rater requirements. CBSI may be of use in large-scale studies of HD.

Для цитирования: Hobbs Nicola Z, Henley Susie M D, Wild Edward J, Leung Kelvin K, Frost Chris, Barker Roger A, Scahill Rachael I, Barnes Josephine, Tabrizi Sarah J, Fox Nick C. Automated quantification of caudate atrophy by local registration of serial MRI: evaluation and application in Huntington's disease.. NeuroImage. 2009. DOI: 10.1016/j.neuroimage.2009.06.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.