DOI 10.1007/s11325-014-1108-4

Медицинская библиотека · Sleep & breathing = Schlaf & Atmung · 2015

Improving detection of obstructive sleep apnoea by overnight oximetry in children using pulse rate parameters.

Sahadan Dg Zuraini, Davey Margot J, Horne Rosemary S C, Nixon Gillian M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Overnight oximetry is a simple tool for investigation of obstructive sleep apnoea (OSA) in children, but only severe cases will be detected, and children with obstructive events resulting in arousal, but not desaturation, will have a normal (inconclusive) result. We hypothesised that pulse rate rises using pulse rate indices per hour (PRI) and pulse rate standard deviation (PR-SD) automatically calculated from commercially available software would improve oximetry as a diagnostic tool.

METHODS

Children having home overnight oximetry for suspected OSA were identified over 12 months, and those with a normal result who went on to have polysomnography (PSG) were included. Oximetry, including PR-SD and PRI (rises of 8, 10 and 15 beats/min per hour), was analyzed using commercially available software. PR parameters were compared between those with OSA (obstructive apnoea-hypopnoea index (OAHI) >1 event/h) and those without OSA.

RESULTS

One hundred sixteen children had normal oximetry, of whom 93 (median age 4.5 years; 55 % M) had PSG. Fifty-seven of 93 (61 %) children had OSA (median OAHI 4.5 events/h, range 1.1-24). PR-SD was not different between the OSA and non-OSA groups (p = 0.87). PRI tended to be higher in those with OSA, but there was considerable overlap between the groups: PRI-8 (mean ± SD 58.5 ± 29.0/h in OSA group vs 48.6 ± 20.2/h in non-OSA group, p = 0.07), PRI-10 (45.1 ± 25.0 vs 36.2 ± 16.7, p = 0.06) and PRI-15 (24.4 ± 14.5 vs 18.9 ± 9.0, p = 0.04). A PRI-15 threshold of >35/h had specificity of 97 % for OSA.

CONCLUSION

The PRI-15 shows promise as an indicator of OSA in children with normal oximetry.

Для цитирования: Sahadan Dg Zuraini, Davey Margot J, Horne Rosemary S C, Nixon Gillian M. Improving detection of obstructive sleep apnoea by overnight oximetry in children using pulse rate parameters.. Sleep & breathing = Schlaf & Atmung. 2015. DOI: 10.1007/s11325-014-1108-4.