MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10875-025-01911-0

Медицинская библиотека · Journal of clinical immunology · 2025

Evaluation of a Multiplex Electrochemiluminescence Assay for Detection of Anti-Pneumococcal Antibodies in the Diagnosis of Selective Polysaccharide Antibody Deficiency.

Perrard Nicolas, Collet Aurore, Stabler Sarah, Poizot Sandrine, Labalette Myriam, Durand Gatien, Batteux Frédéric, Mirgot Floriane, Lopez Benjamin, Dubucquoi Sylvain, Chevrier Lucie, Lefèvre Guillaume

СтатьяОценочное исследованиеПеревод в очереди

Аннотация

Streptococcus pneumoniae can be responsible for severe infections, especially in patients with primary antibody deficiencies like selective anti-polysaccharide antibodies deficiency (SPAD). The reference method recommaned by the World Health Organization for assessment of anti-pneumococcal capsular polysaccharides (PCPs) IgG antibodies is a standardized serotype-specific ELISA (WHO-SSA), but this manual method is time-consuming and limit the number of evaluated PCPs. We aim to evaluate the performance values of a multiplex assay based on electrochemiluminescence (ECL-plex). A panel of 164 sera from 82 patients sampled before and 4-8 weeks after immunization by the 23-valent pneumococcal polysaccharide vaccine (PPV23) were assessed by the reference WHO-SSA (7 to 13 serotypes) and by an 18-plex ECL assay (18 serotypes). All patients had normal serum Ig/subclasses levels and were classified as good (n = 43) or poor responders (n = 39, i.e. SPAD patients) according to the American Academy of Asthma, Allergy and Immunology's (AAAAI) current guidelines. We observed excellent correlations between the two methods for anti-PCPs titers against 7 serotypes (r = 0.88 [95% CI: 0.87-0.90], n = 124 sera) and 13 serotypes (r = 0.87 [0.87-0.89], n = 40 sera). Using the AAAAI's guidelines for interpretation, the test performance of the 18-plex ECL assay for SPAD diagnosis showed a sensitivity of 95% and specificity of 84%, positive and negative predictive values of 84% and 95%, respectively. The percentage of agreement was 89% between the SSA and the 18-plex ECL assay. The 18-plex ECL assay is a reliable, rapid, and simple method for evaluating anti-PCPs response and screening for SPAD diagnosis.

Для цитирования: Perrard Nicolas, Collet Aurore, Stabler Sarah, Poizot Sandrine, Labalette Myriam, Durand Gatien, Batteux Frédéric, Mirgot Floriane, Lopez Benjamin, Dubucquoi Sylvain, Chevrier Lucie, Lefèvre Guillaume. Evaluation of a Multiplex Electrochemiluminescence Assay for Detection of Anti-Pneumococcal Antibodies in the Diagnosis of Selective Polysaccharide Antibody Deficiency.. Journal of clinical immunology. 2025. DOI: 10.1007/s10875-025-01911-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.