Sonographic harmonic grey scale imaging of brain perfusion: scope of a new method demonstrated in selected cases.

Stolz E, Allendörfer J, Jauss M, Traupe H, Kaps M

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

AIM: Transient response harmonic transcranial sonography is a new bed-side technique which provides information on brain tissue perfusion. This paper demonstrates the scope of perfusion transcranial sonography (p-TCS).

METHODS

P-TCS was performed in an axial insonation plane through the thalamus and third ventricle in a case with Moyamoya disease and a patient with bilateral thalamic oedema due to thrombosis of the internal cerebral veins, and compared to results in 10 healthy controls. Signal increase induced by a bolus of an echo-contrast agent (Optison trade mark ) was quantified in regions of interest (ROI) in the thalamus (TH), lentiform nucleus (LN) and the cerebral white matter (WM).

RESULTS

In Moyamoya disease p-TCS could demonstrate a decreased perfusion in the WM and LN as a result of bilateral, high-grade stenoses of the intracranial part of the internal carotid artery. Peak intensity was increased in the TH due to collateral cross-over flow from the vertebrobasilar system. TH perfusion was decreased in thrombosis of the internal cerebral vein thrombosis with normal LN perfusion. The extention of the thalamic oedema into the white matter could also be demonstrated by decreased perfusion in the adjacent WM. ROI ratios of different tissues proved helpful in quantifying the perfusion results.

CONCLUSION

P-TCS is a new, promising technique that can supply information on pathological brain tissue perfusion at the patient's bed-side.

Для цитирования: Stolz E, Allendörfer J, Jauss M, Traupe H, Kaps M. Sonographic harmonic grey scale imaging of brain perfusion: scope of a new method demonstrated in selected cases.. Ultraschall in der Medizin (Stuttgart, Germany : 1980). 2002. DOI: 10.1055/s-2002-35058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.