MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1086/523272

Медицинская библиотека · Infection control and hospital epidemiology · 2007

Double-blind, randomized, crossover trial of 3 hand rub formulations: fast-track evaluation of tolerability and acceptability.

Pittet Didier, Allegranzi Benedetta, Sax Hugo, Chraiti Marie-Noelle, Griffiths William, Richet Hervé, World Health Organization Global Patient Safety Challenge Alcohol-Based Handrub Task Force

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To compare healthcare workers' skin tolerance for and acceptance of 3 alcohol-based hand rub formulations.

DESIGN

Double-blind, randomized, crossover clinical trial.

SETTING

Intensive care unit in a university hospital.

PARTICIPANTS

Thirty-eight healthcare workers (HCWs).

INTERVENTION: A total of 3 alcohol-based hand rub formulations (hereafter, formulations A, B, and C) were used in random order for 3-5 consecutive working days during regular nursing shifts. Formulations A and B contained the same emollient, and formulations B and C contained the same alcohol at the same concentration. Use of each test formulation was separated by a "washout" period of at least 2 days. A visual assessment of skin integrity by a blinded observer using a standard 6-item scale was conducted before and after the use of each formulation. Univariate and multivariate analyses were used for the assessment of risk factors for skin alteration, and product acceptability was assessed by use of a customized questionnaire after the use of each formulation.

RESULTS

Thirty-eight HCWs used each of 3 formulations for a median of 3 days (range, 3-5 days). The mean amount of product used daily (+/-SD) was 54.9+/-23.5 mL (median, 50.9 mL). Both subjective and objective evaluation of skin conditions after use showed lower HCW tolerance for product C. Male sex (odds ratio [OR], 3.17 [95% confidence interval {CI}, 1.1-8.8]), fair or very fair skin (OR, 3.01 [95% CI, 1.1-7.9]), skin alteration before hand rub use (OR, 3.73 [95% CI, 1.7-8.1]), and use of formulation C (OR, 8.79 [95% CI, 2.7-28.4]) were independently associated with skin alteration.

CONCLUSIONS

This protocol permits a fast-track comparison of HCWs' skin tolerance for different alcohol-based hand rub formulations that are used in healthcare settings. The emollient in formulation C may account for its inferior performance.

Для цитирования: Pittet Didier, Allegranzi Benedetta, Sax Hugo, Chraiti Marie-Noelle, Griffiths William, Richet Hervé, World Health Organization Global Patient Safety Challenge Alcohol-Based Handrub Task Force. Double-blind, randomized, crossover trial of 3 hand rub formulations: fast-track evaluation of tolerability and acceptability.. Infection control and hospital epidemiology. 2007. DOI: 10.1086/523272.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.