MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1756-0500-7-127

Медицинская библиотека · BMC research notes · 2014

Using NU-KNIT® for hemostasis around recurrent laryngeal nerve during transthoracic esophagectomy with lymphadenectomy for esophageal cancer.

Rino Yasushi, Yukawa Norio, Sato Tsutomu, Yamamoto Naoto, Tamagawa Hiroshi, Hasegawa Shinichi, Oshima Takashi, Yoshikawa Takaki, Masuda Munetaka, Imada Toshio

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We thought that using electrocautery for hemostasis caused recurrent laryngeal nerve palsy. We reflected the prolonged use of electrocautery and employed NU-KNIT® to achieve hemostasis nearby the recurrent laryngeal nerve. We assessed that using NU-KNIT® hemostasis prevented or not postoperative recurrent laryngeal nerve palsy, retrospectively. The present study was evaluated to compare using electrocautery hemostasis with using NU-KNIT® hemostasis during lymphadenectomy along recurrent laryngeal nerve. The variables compared were morbidity rate of recurrent laryngeal nerve palsy, operation time, and blood loss.

RESULTS

We use NU-KNIT® to achieve hemostasis without strong compression. This group is named group N. On the other hand, we use electrocautery to achieve hemostasis. This group is named group E. Complication rate of recurrent laryngeal nerve palsy was higher in group E (55.6%) than group N (5.3%) (p = 0.007).

CONCLUSIONS

Even hemostasis using NU-KNIT® was slightly more time-consuming than using electrocautery, we concluded that it would be useful to prevent recurrent laryngeal nerve palsy.

Для цитирования: Rino Yasushi, Yukawa Norio, Sato Tsutomu, Yamamoto Naoto, Tamagawa Hiroshi, Hasegawa Shinichi, Oshima Takashi, Yoshikawa Takaki, Masuda Munetaka, Imada Toshio. Using NU-KNIT® for hemostasis around recurrent laryngeal nerve during transthoracic esophagectomy with lymphadenectomy for esophageal cancer.. BMC research notes. 2014. DOI: 10.1186/1756-0500-7-127.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.