Annals of vascular surgery · 2020

Risk Factors for Closure Failure following Percutaneous Transfemoral Transcatheter Aortic Valve Implantation.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Cheol Ho, Ko Young-Guk, Park Yeonjeong, Shim Chi Young, Hong Geu-Ru, Lee Seung Hyun, Lee Sak, Jung Hae Won, Hong Sung-Jin, Ahn Chul-Min, Kim Jung-Sun, Kim Byeong-Keuk, Choi Donghoon, Hong Myeong-Ki, Jang Yangsoo

Аннотация

BACKGROUND: The percutaneous access site of transfemoral transcatheter aortic valve implantation (TAVI) procedures is commonly closed using a preclosure technique with suture-type closure devices. We sought to evaluate the predictors and outcomes of percutaneous closure device (PCD) failure during transfemoral TAVI.

METHODS AND RESULTS: This single-center retrospective analysis included 184 patients who underwent transfemoral TAVI using 2 ProGlide sutures for severe aortic stenosis between July 2011 and September 2018. PCD failure was observed in 11.4%. The causes of PCD failure included 5 cases of insufficient hemostasis, 13 cases of arterial stenosis or occlusion, and 3 cases of dissection. Closure failures were managed by surgical repair in 10 patients and endovascular treatment in 11 patients. In a multivariate binary logistic model, a minimum lumen diameter of the common femoral artery (CFA) (odds ratio [OR] 0.35, 95% confidence interval [CI] 0.15-0.83, P = 0.017) and left femoral access (OR 2.89, 95% CI 1.01-8.30, P = 0.048) was identified as a predictor of PCD failure. PCD failure was not associated with increased mortality (0% vs. 2.5%, P = 1.000) or a major adverse cardiovascular event (MACE; 4.8% vs. 4.3%, P = 1.000) at 30 days.

CONCLUSIONS: PCD failures were not uncommon in patients undergoing percutaneous transfemoral TAVI. Small CFA diameter and left femoral access are predictors of PCD failure. However, PCD failures were not associated with increased mortality or MACE.