MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2019.08.020

Медицинская библиотека · JACC. Clinical electrophysiology · 2019

Safety and In-Hospital Outcomes of Transvenous Lead Extraction for Cardiac Implantable Device-Related Infections: Analysis of 13 Years of Inpatient Data in the United States.

Hosseini Seyed Mohammadreza, Rozen Guy, Kaadan M Ihsan, Galvin Jennifer, Ruskin Jeremy N

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to investigate the safety and in-hospital outcomes of transcutaneous lead extraction (TLE) associated with device-related infection (DRI) in the United States from 2003 to 2015.

BACKGROUND

DRI remains the most serious complication and the most common indication for lead extraction in patients with cardiac implantable electronic devices. The rates of DRI and associated lead extraction have been growing in line with the increasing number of cardiac implantable electronic device implantations worldwide.

METHODS

Data for this study were drawn from the National (Nationwide) Inpatient Sample. The International Classification of Diseases-9th Revision-Clinical Modification coding system was used to identify hospitalizations with TLE for DRI and to investigate the rates of major adverse events.

RESULTS

From a total of approximately 100 million unweighted hospitalizations over the 13-year study period, 12,257 unweighted observations were identified. This represents 59,082 (95% confidence interval [CI]: 58,982 to 59,182) patients who underwent TLE for DRI during the study period. A large majority of patients (75%) were older than 60 years. Patients were predominantly male (70%) and Caucasian (76%), and 80% had at least 1 comorbidity. The median length of stay was 8 days (interquartile range 5 to 14 days). At least 1 major adverse event occurred in 10.42% of procedures. The all-cause in-hospital mortality rate was 4.11%. Independent predictors of mortality were weight loss (adjusted odds ratio [aOR]: 4.02; 95% CI: 3.13 to 5.17), congestive heart failure (aOR: 3.28; 95% CI: 2.48 to 4.34), chronic kidney disease (aOR: 2.09; 95% CI: 1.70 to 2.56), pericardial complications (aOR: 2.87; 95% CI: 1.79 to 4.61), and procedure-related pulmonary injury (aOR: 2.06; 95% CI: 1.25 to 3.40).

CONCLUSIONS

These results reflect the high rate of complications and mortality for TLE due to DRI in real-world experience, highlighting the importance of comorbidities, especially congestive heart failure and chronic kidney disease, as significant predictors of mortality in these patients.

Для цитирования: Hosseini Seyed Mohammadreza, Rozen Guy, Kaadan M Ihsan, Galvin Jennifer, Ruskin Jeremy N. Safety and In-Hospital Outcomes of Transvenous Lead Extraction for Cardiac Implantable Device-Related Infections: Analysis of 13 Years of Inpatient Data in the United States.. JACC. Clinical electrophysiology. 2019. DOI: 10.1016/j.jacep.2019.08.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.