MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mao.0000000000002722

Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2020

OTOPLAN in Cochlear Implantation for Far-advanced Otosclerosis.

Lovato Andrea, Marioni Gino, Gamberini Lisa, Bonora Chiara, Genovese Elisabetta, de Filippis Cosimo

СтатьяПеревод в очереди

Аннотация

AIM: To evaluate OTOPLAN software in the surgical planning of far-advanced otosclerosis (FAO) candidates to cochlear implant (CI) were considered. We aimed to preliminarily investigate if this software could influence the electrode length choice, or predict surgical difficulties.

METHODS

We reviewed the outcome of five consecutive FAO patients that underwent unilateral CI. OTOPLAN was used to evaluate preoperative computed tomography imaging. A comparison was made with historical data (eight FAO patients).

RESULTS

The mean cochlear duct length estimated by OTOPLAN was 32.4 mm. Evaluating OTOPLAN reconstructed images, we ruled out cochlear lumen fibrosis/ossification in three FAO patients and the longest electrodes according to cochlear dimensions were preferred. We disclosed fibrosis in the middle and apical turns of two patients. These findings allowed us to change surgical plans, choosing a shorter electrode (24 and 28 mm instead of 31 mm) to avoid incomplete insertion due to cochlear fibrosis. OTOPLAN reconstructed images identified preoperatively the two patients with round window niche ossification that required additional drilling during surgery. In the present series, we experienced no incomplete insertion. In two cases out of eight historical FAO patients, array insertion (24 mm) was incomplete. One years after unilateral CI, the mean speech reception threshold and disyllabic word recognition score of the five considered FAO patients were 36 dB and 94%, respectively (39 dB and 84% for the eight historical patients). There was no facial nerve stimulation or any other complication during the 1-year follow-up.

CONCLUSION

According to our preliminary results, OTOPLAN was useful for the appropriate choice of array length.

Для цитирования: Lovato Andrea, Marioni Gino, Gamberini Lisa, Bonora Chiara, Genovese Elisabetta, de Filippis Cosimo. OTOPLAN in Cochlear Implantation for Far-advanced Otosclerosis.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2020. DOI: 10.1097/mao.0000000000002722.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.