The American journal of gastroenterology · 2005
The limitations of gastro-jejunal (G-J) feeding tubes in children: a 9-year pediatric hospital database analysis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Fortunato John E, Darbari Anil, Mitchell Sally E, Thompson Richard E, Cuffari Carmen
Аннотация
BACKGROUND: A gastro-jejunal (G-J) feeding tube is a safe and useful temporizing method of providing enteral access in children. Although G-J tubes are often used to obviate the need for a surgical jejunostomy, their long-term use is often associated with mechanical failure.
AIM: To review the clinically effective durability of G-J feeding tubes in providing enteral access in children.
METHODS: We performed a retrospective review of 102 patients at the Johns Hopkins Children's Center from 1994-2003 whose underlying diagnosis necessitated the need for postpyloric enteral access.
RESULTS: Long-term follow-up was obtained in 85 (48 M; 37 F) patients with a median (range) age of 2.0 (0.1-18.0) yr. The most common indication for G-J tube placement was gastroesophageal reflux with aspiration in 51 patients and feeding intolerance and vomiting in 19 patients. The mean (range) number of tube replacements was 2.2 (1-14) over a median (range) duration of follow-up of 39 (2-474) days. The indication for G-J tube replacement included: tube displacement (58), a clogged tube (41), and a cracked tube or ruptured balloon (35). In 52 cases, the cause for G-J tube replacement was undetermined.
CONCLUSIONS: G-J feeding tubes are associated with the frequent need for tube maintenance and replacement and may not be the most feasible clinical option in providing long-term (>1 month) enteral access in children intolerant to gastrostomy tube feeds. Future studies are needed to develop innovative percutaneous jejunostomy tube placement techniques that facilitate long-term enteral access.
AIM: To review the clinically effective durability of G-J feeding tubes in providing enteral access in children.
METHODS: We performed a retrospective review of 102 patients at the Johns Hopkins Children's Center from 1994-2003 whose underlying diagnosis necessitated the need for postpyloric enteral access.
RESULTS: Long-term follow-up was obtained in 85 (48 M; 37 F) patients with a median (range) age of 2.0 (0.1-18.0) yr. The most common indication for G-J tube placement was gastroesophageal reflux with aspiration in 51 patients and feeding intolerance and vomiting in 19 patients. The mean (range) number of tube replacements was 2.2 (1-14) over a median (range) duration of follow-up of 39 (2-474) days. The indication for G-J tube replacement included: tube displacement (58), a clogged tube (41), and a cracked tube or ruptured balloon (35). In 52 cases, the cause for G-J tube replacement was undetermined.
CONCLUSIONS: G-J feeding tubes are associated with the frequent need for tube maintenance and replacement and may not be the most feasible clinical option in providing long-term (>1 month) enteral access in children intolerant to gastrostomy tube feeds. Future studies are needed to develop innovative percutaneous jejunostomy tube placement techniques that facilitate long-term enteral access.