The Journal of thoracic and cardiovascular surgery · 2013
Hemodynamic performance and outcome of percutaneous versus surgical stentless bioprostheses for aortic stenosis with anticipated patient-prosthesis mismatch.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Finkelstein Arie, Schwartz Arie Lorin, Uretzky Gideon, Banai Shmuel, Keren Gad, Kramer Amir, Topilsky Yan
Аннотация
OBJECTIVES: We aimed to compare the performance and midterm survival of transcutaneous aortic valve replacement (TAVR) and surgically implanted stentless aortic valve replacement (SAVR) for severe aortic stenosis in patients anticipated to have patient-prosthesis mismatch (PPM).
METHODS: A retrospective analysis was performed of 86 and 49 consecutive TAVR and SAVR patients with severe aortic stenosis and calculated minimal effective orifice area larger than the best projected effective orifice area. Cox hazard analyses were used to assess the effect of TAVR versus SAVR on outcome.
RESULTS: The peak and mean transprosthetic gradient at discharge were lower (P < .001 for both) in the TAVR group. Mild or greater aortic regurgitation was more frequent in the TAVR group (61% vs 7%; P < .0001). At 3 months of follow-up, the mean gradient in the TAVR group was similar to that of the SAVR group but the prevalence of aortic regurgitation was still higher. The unadjusted 3-year survival rate was superior in the SAVR versus TAVR group (91.6% ± 4% vs 67.0% ± 7%; P = .01). Adjustments for both age and comorbidity resulted in loss of the difference in mortality between the 2 groups.
CONCLUSIONS: In patients with anticipated PPM, TAVR offers an immediate lower incidence of PPM than SAVR but a greater prevalence of aortic regurgitation. The differences in transaortic gradients became nonsignificant 3 months postoperatively. The question of whether TAVR is a suitable substitute for SAVR in patients with anticipated PPM, in particular, those who are older and sicker, warrants additional investigation.
METHODS: A retrospective analysis was performed of 86 and 49 consecutive TAVR and SAVR patients with severe aortic stenosis and calculated minimal effective orifice area larger than the best projected effective orifice area. Cox hazard analyses were used to assess the effect of TAVR versus SAVR on outcome.
RESULTS: The peak and mean transprosthetic gradient at discharge were lower (P < .001 for both) in the TAVR group. Mild or greater aortic regurgitation was more frequent in the TAVR group (61% vs 7%; P < .0001). At 3 months of follow-up, the mean gradient in the TAVR group was similar to that of the SAVR group but the prevalence of aortic regurgitation was still higher. The unadjusted 3-year survival rate was superior in the SAVR versus TAVR group (91.6% ± 4% vs 67.0% ± 7%; P = .01). Adjustments for both age and comorbidity resulted in loss of the difference in mortality between the 2 groups.
CONCLUSIONS: In patients with anticipated PPM, TAVR offers an immediate lower incidence of PPM than SAVR but a greater prevalence of aortic regurgitation. The differences in transaortic gradients became nonsignificant 3 months postoperatively. The question of whether TAVR is a suitable substitute for SAVR in patients with anticipated PPM, in particular, those who are older and sicker, warrants additional investigation.
Предметные рубрики MeSH
Age FactorsAortic Valve InsufficiencyAortic Valve StenosisBioprosthesisCardiac CatheterizationChi-Square DistributionComorbidityEchocardiography, DopplerHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHumansKaplan-Meier EstimatePatient SelectionProportional Hazards ModelsProsthesis DesignRetrospective StudiesRisk FactorsSeverity of Illness IndexTime FactorsTreatment Outcome