Медицинская библиотека · Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2020

Evaluation of Artificial Fixation of the Incus and Malleus With Minimally Invasive Intraoperative Laser Vibrometry (MIVIB) in a Temporal Bone Model.

Gladiné Kilian, Wales Jeremy, Silvola Juha, Muyshondt Pieter G G, Topsakal Vedat, Van De Heyning Paul, Dirckx Joris J J, von Unge Magnus

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A significant number of adults suffer from conductive hearing loss due to chronic otitis media, otosclerosis, or other pathologies. An objective measurement of ossicular mobility is needed to avoid unnecessarily invasive middle ear surgery and to improve hearing outcomes.

METHODS

Minimally invasive intraoperative laser vibrometry provides a method that is compatible with middle ear surgery, where the tympanic membrane is elevated. The ossicles were driven by a floating mass transducer and their mobility was measured using a laser Doppler vibrometer. Utilising this method, we assessed both the absolute velocities of the umbo and incus long process as well as the incus-to-umbo velocity ratio during artificial fixation of the incus alone or incus and malleus together.

RESULTS

The reduction of absolute velocities was 8 dB greater at the umbo and 17 dB at the incus long process for incus-malleus fixations when compared with incus fixation alone. Incus fixation alone resulted in no change to the incus-to-umbo velocity ratio where incus-malleus fixations reduced this ratio (-11 dB). The change in incus velocity was shown to be the most suitable parameter to distinguish between incus fixation and incus-malleus fixation. When the whole frequency range was analyzed, one could also differentiate these two fixations from previously published stapes fixation, where the higher frequencies were less affected.

CONCLUSION

Minimally invasive intraoperative laser vibrometry provides a promising objective analysis of ossicular mobility that would be useful intraoperatively.

Для цитирования: Gladiné Kilian, Wales Jeremy, Silvola Juha, Muyshondt Pieter G G, Topsakal Vedat, Van De Heyning Paul, Dirckx Joris J J, von Unge Magnus. Evaluation of Artificial Fixation of the Incus and Malleus With Minimally Invasive Intraoperative Laser Vibrometry (MIVIB) in a Temporal Bone Model.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2020. DOI: 10.1097/mao.0000000000002444.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.