DOI 10.1111/echo.14403

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2019

Echocardiographic mimicker of thrombus on a mechanical aortic valve prosthesis due to cavitation: A paradoxical phenomenon of pressure recovery.

Wang Zhenzhen, Ayoub Chadi, Thaden Jeremy J, Alsidawi Said, Miller Fletcher A, Sinak Lawrence J, Rihal Charanjit S, Melduni Rowlens M

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

We describe a case of a mass-like echocardiographic density on a mechanical prosthetic aortic valve. We initially suspected a thrombus vs vegetation on transthoracic echocardiography, but after transesophageal echocardiography, the density was subsequently determined to be cavitation by reviewing the initial images in slow motion.

Для цитирования: Wang Zhenzhen, Ayoub Chadi, Thaden Jeremy J, Alsidawi Said, Miller Fletcher A, Sinak Lawrence J, Rihal Charanjit S, Melduni Rowlens M. Echocardiographic mimicker of thrombus on a mechanical aortic valve prosthesis due to cavitation: A paradoxical phenomenon of pressure recovery.. Echocardiography (Mount Kisco, N.Y.). 2019. DOI: 10.1111/echo.14403.