European radiology · 2020

Post-processing of computed tomography perfusion in patients with acute cerebral ischemia: variability of inter-reader, inter-region of interest, inter-input model, and inter-software.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Zhong-Ping, Shi Zhen-Zhen, Li Yun-Geng, Guo Yan, Tong Dan

Аннотация

OBJECTIVE: To determine the reproducibility of quantitative computed tomography perfusion (CTP) parameters generated using different post-processing methods and identify the relative impact of subjective factors on the robustness of CTP parameters in acute ischemic stroke (AIS).

MATERIALS AND METHODS: A total of 80 CTP datasets from patients with AIS or transient ischemic attack (TIA) were retrospectively post-processed by two observers using different regions of interest (ROI) types, input models, and software. The CTP parameters were derived for 10 parenchymal ROIs. The intra-class correlation coefficients (ICCs) were used to assess the reproducibility of the CTP parameters for various post-processing methods. The Spearman correlation test was used to detect potential relationships between software and input models.

RESULTS: The ICCs with 95% confidence intervals (CIs) were 0.94 (0.93-0.96), 0.94 (0.92-0.96), 0.82 (0.79-0.86), and 0.87 (0.85-0.90) for inter-reader agreement by using elliptic ROI, irregular ROI, single-input model, and dual-input model, respectively. The ICCs with 95% CI were 0.98 (0.98-0.98), 0.46 (0.43-0.50), and 0.25 (0.20-0.30) for inter-ROI type, inter-input model, and inter-software agreement, respectively.

CONCLUSIONS: Although the CTP parameters were stable when measured using different readers with different ROI types, they varied for different input models and software. The standardization of CTP post-processing is essential to reduce variability of CTP values.

KEY POINTS: • The CTP parameters derived by different readers with different ROI types have agreements that range from good to excellent. • The CTP parameters derived from different input models and software programs have poor agreement but significant correlations.