MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.14027

Медицинская библиотека · Contact dermatitis · 2022

Patch testing with the Japanese baseline series 2015: A 4-year experience.

Ito Akiko, Suzuki Kayoko, Matsunaga Kayoko, Yagami Akiko, Ito Takashi, Tamagawa-Mineoka Risa, Adachi Atsuko, Sugiura Mariko, Miyazawa Hitoshi, Kato Atsuko, Nakada Tokio, Nishioka Kazue, Kubota Yumiko, Matsukura Setsuko, Watanabe Yuko, Asada Hideo, Kanto Hiromi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The Japanese baseline series (JBS), established in 1994, was updated in 2008 and 2015. The JBS 2015 is a modification of the thin-layer rapid-use epicutaneous (TRUE) test (SmartPractice Denmark, Hillerød, Denmark). No nationwide studies concerning the TRUE test have previously been reported.

OBJECTIVES

To determine the prevalence of sensitizations to JBS 2015 allergens from 2015 to 2018.

METHODS

We investigated JBS 2015 patch test results using the web-registered Skin Safety Care Information Network (SSCI-Net) from April 2015 to March 2019.

RESULTS

Patch test results of 5865 patients were registered from 63 facilities. The five allergens with the highest positivity rates were gold sodium thiosulfate (GST; 25.7%), nickel sulfate (24.5%), urushiol (9.1%), p-phenylenediamine (PPD; 8.9%), and cobalt chloride (8.4%). The five allergens with the lowest positivity rates were mercaptobenzothiazole (0.8%), formaldehyde (0.9%), paraben mix (1.1%), mercapto mix (1.1%), and PPD black rubber mix (1.4%).

CONCLUSIONS

Nickel sulfate and GST had the highest positivity rates. The JBS 2015, including a modified TRUE test, is suitable for baseline series patch testing.

Для цитирования: Ito Akiko, Suzuki Kayoko, Matsunaga Kayoko, Yagami Akiko, Ito Takashi, Tamagawa-Mineoka Risa, Adachi Atsuko, Sugiura Mariko, Miyazawa Hitoshi, Kato Atsuko, Nakada Tokio, Nishioka Kazue, Kubota Yumiko, Matsukura Setsuko, Watanabe Yuko, Asada Hideo, Kanto Hiromi. Patch testing with the Japanese baseline series 2015: A 4-year experience.. Contact dermatitis. 2022. DOI: 10.1111/cod.14027.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.