Effective Apixaban removal using hemoadsorption during emergent open-heart surgery: a case report and narrative literature review.

Mendes Vitor, Mamode Jaid, Jolou Jalal, Malki Mourad, Ellenberger Christoph, Cikirikcioglu Mustafa, Huber Christoph

ОбзорКлинический случайСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The management of hemostasis in patients medicated with apixaban (Eliquis) undergoing emergency cardiac surgery is exceedingly difficult. The body's natural elimination pathways for apixaban prove ineffective in emergency situations, and the impact of hemodialysis is limited. The application of Cytosorb® may attenuate the concentration of apixaban, thereby facilitating the stabilization of these patients.

CASE PRESENTATION: An 84-year-old man treated with apixaban, underwent emergency ascending aorta replacement surgery due to an acute type A aortic dissection. To address the challenges induced by apixaban, we integrated Cytosorb® cartridge into the Cardiopulmonary bypass circuit. There was a 63.7% decrease in perioperative apixaban-specific anti-factor Xa activity. The patient's postoperative course was favourable.

CONCLUSION

Hemoadsorption with Cytosorb® may offers a safe and feasible approach for reducing apixaban concentration in emergency cardiac surgery, thereby mitigating the risk of hemorrhagic complications.

Для цитирования: Mendes Vitor, Mamode Jaid, Jolou Jalal, Malki Mourad, Ellenberger Christoph, Cikirikcioglu Mustafa, Huber Christoph. Effective Apixaban removal using hemoadsorption during emergent open-heart surgery: a case report and narrative literature review.. Journal of cardiothoracic surgery. 2024. DOI: 10.1186/s13019-024-02748-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.