MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00268-011-1365-3

Медицинская библиотека · World journal of surgery · 2012

Parathyroid four-dimensional computed tomography: evaluation of radiation dose exposure during preoperative localization of parathyroid tumors in primary hyperparathyroidism.

Mahajan Amit, Starker Lee F, Ghita Monica, Udelsman Robert, Brink James A, Carling Tobias

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Parathyroid four-dimensional computed tomography (4DCT) provides greater sensitivity than sestamibi with single photon emission CT (SPECT, or SeS) for preoperative localization of parathyroid tumors in patients with primary hyperparathyroidism (PHPT). The radiation dose imparted to the patient during preoperative parathyroid imaging, however, has not been analyzed.

METHODS

Patients with biochemically unequivocal PHPT referred for minimally invasive parathyroidectomy underwent 4DCT or SeS. 4DCT was performed using a 64 detector row CT scanner, and SeS used a standardized protocol of 20 mCi of technetium-99m followed by planar and SPECT imaging. The CT radiation dose was estimated using the Imaging Performance Assessment of CT Scanners (ImPACT) calculator, and the SeS dose was estimated using the US Nuclear Regulatory Commission Regulation (NUREG) method.

RESULTS

The calculated effective doses of 4DCT and SeS were 10.4 and 7.8 mSv, respectively, in contrast to an estimated annual background radiation exposure of approximately 3 mSv. The dose to the thyroid with 4DCT, however, was about 57 times higher (92.0 vs. 1.6 mGy) than that with SeS. Based on age- and sex-dependent risk factors, the calculated risk of 4DCT-related thyroid cancer developing in a 20 year old woman was 1,040/million (i.e., about 0.1%).

CONCLUSIONS

4DCT, a superior preoperative imaging modality for locating parathyroid tumors, imparts a significantly higher thyroid radiation dose than SeS. Given the enhanced risk of thyroid cancer in individuals with radiation exposure at a young age, 4DCT should be used judiciously in young PHPT patients.

Для цитирования: Mahajan Amit, Starker Lee F, Ghita Monica, Udelsman Robert, Brink James A, Carling Tobias. Parathyroid four-dimensional computed tomography: evaluation of radiation dose exposure during preoperative localization of parathyroid tumors in primary hyperparathyroidism.. World journal of surgery. 2012. DOI: 10.1007/s00268-011-1365-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.