MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejo/cjad075

Медицинская библиотека · European journal of orthodontics · 2024

Cervical headgear effectiveness in distalizing molars in relation to patient compliance.

Gratsia Sofia, Cocos Alina, Vastardis Heleni, Halazonetis Demetrios

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The purpose of this study was to measure the effectiveness of the cervical headgear for distalizing first permanent maxillary molars in relation to hours of use.

METHODS

This was a one-centre, prospective, clinical study conducted at the Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece. Participants (N = 26; 17 females, 9 males) were patients with no history of orthodontic treatment, no syndromes or clefts, and Angle's Class II malocclusion, where the treatment plan included a cervical headgear. They were instructed to wear the appliance for at least 12 h per day. A TheraMon® microsensor was embedded in the headgear's strap to objectively measure wear-time. To measure tooth movement, pre- and post-treatment digital models were superimposed, using the palate as a reference area; translation and rotation were measured along three axes. Superimposition and movement measurements were made with the Viewbox 4 software.

RESULTS

Average treatment time and headgear wear were 130 days and 55 days, respectively, i.e. 10.1 h/day. During this period, distal movement averaged 1.75 mm with high variability (min 0.2 mm, max 4.5 mm). Distal tipping and rotation had an average of approximately 5 °C. Cumulative headgear wear was significantly correlated with distal movement (r2 = 0.32, P < .002), distal tipping (r2 = 0.27, P < .01), and distal rotation around the long axis of the tooth (r2 = 0.20, P < .05).

CONCLUSION

Compliance is critical for having a successful clinical outcome. Distalization of the molar with a cervical headgear is correlated with the cumulative hours of appliance use, with hours per day being a weaker predictor.

Для цитирования: Gratsia Sofia, Cocos Alina, Vastardis Heleni, Halazonetis Demetrios. Cervical headgear effectiveness in distalizing molars in relation to patient compliance.. European journal of orthodontics. 2024. DOI: 10.1093/ejo/cjad075.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.