The American journal of gastroenterology · 2023

Interrater Reliability of Functional Lumen Imaging Probe Panometry and High-Resolution Manometry for the Assessment of Esophageal Motility Disorders.

СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chen Joan W, Khan Abraham, Chokshi Reena V, Clarke John O, Fass Ronnie, Garza Jose M, Gupta Milli, Gyawali C Prakash, Jain Anand S, Katz Philip, Konda Vani, Lazarescu Adriana, Lynch Kristle L, Schnoll-Sussman Felice, Spechler Stuart J, Vela Marcelo F, Yadlapati Rena, Schauer Jacob M, Kahrilas Peter J, Pandolfino John E, Carlson Dustin A

Аннотация

INTRODUCTION: High-resolution manometry (HRM) and functional lumen imaging probe (FLIP) are primary and/or complementary diagnostic tools for the evaluation of esophageal motility. We aimed to assess the interrater agreement and accuracy of HRM and FLIP interpretations.

METHODS: Esophageal motility specialists from multiple institutions completed the interpretation of 40 consecutive HRM and 40 FLIP studies. Interrater agreement was assessed using intraclass correlation coefficient (ICC) for continuous variables and Fleiss' κ statistics for nominal variables. Accuracies of rater interpretation were assessed using the consensus of 3 experienced raters as the reference standard.

RESULTS: Fifteen raters completed the HRM and FLIP studies. An excellent interrater agreement was seen in supine median integral relaxation pressure (ICC 0.96, 95% confidence interval 0.95-0.98), and a good agreement was seen with the assessment of esophagogastric junction (EGJ) outflow, peristalsis, and assignment of a Chicago Classification version 4.0 diagnosis using HRM (κ = 0.71, 0.75, and 0.70, respectively). An excellent interrater agreement for EGJ distensibility index and maximum diameter (0.91 [0.90-0.94], 0.92 [0.89-0.95]) was seen, and a moderate-to-good agreement was seen in the assignment of EGJ opening classification, contractile response pattern, and motility classification (κ = 0.68, 0.56, and 0.59, respectively) on FLIP. Rater accuracy for Chicago Classification version 4.0 diagnosis on HRM was 82% (95% confidence interval 78%-84%) and for motility diagnosis on FLIP Panometry was 78% (95% confidence interval 72%-81%).

DISCUSSION: Our study demonstrates high levels of interrater agreement and accuracy in the interpretation of HRM and FLIP metrics and moderate-to-high levels for motility classification in FLIP, supporting the use of these approaches for primary or complementary evaluation of esophageal motility disorders.