MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1245/s10434-023-13405-7

Медицинская библиотека · Annals of surgical oncology · 2023

The Use of Indocyanine Green and Near-Infrared Fluorescence Imaging Versus Blue Dye in Sentinel Lymph Node Biopsy in Cutaneous Melanoma: A Retrospective, Cohort Study.

Fadel Michael G, Rauf Sidra, Mohamed Hesham S, Yusuf Siraj, Hayes Andrew J, Power Kieran, Smith Myles J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of indocyanine green (ICG) and near-infrared fluorescence imaging is a promising option for sentinel lymph node (SLN) mapping in cutaneous melanoma. The study objective was to compare the performance of ICG and blue dye at detecting SLNs with radioisotope nanocolloid (technetium-99).

METHODS

Between April 2018 and June 2022, 293 consecutive patients with cutaneous melanoma (Breslow thickness ≥ 0.8 mm) underwent wide local excision and SLN biopsy. Patients were divided into group A (ICG; n = 122) and group B (blue dye; n = 163). All patients underwent SPECT/CT imaging preoperatively. SLN detection parameters and complications were compared between the groups.

RESULTS

A total of 285 patients had complete data and were included in the analysis. The median age was 62.0 (range 10-91) years, and 139 (48.8%) were female patients. The mean Breslow thickness was 2.6 mm, 89 (31.2%) patients had ulceration, and 179 (62.8%) patients had mitosis ≥ 1 mm2. The mean number of SLNs detected per patient in group A was 1.58 and group B was 1.48. In groups A and B, the SLN detection rate was 96.7% versus 89.6% (p = 0.022) and the pathological SLN detection rate was 92.3% versus 97.1% (p = 0.481), respectively.

CONCLUSIONS

ICG had a higher SLN detection rate and equal pathological SLN detection rate to blue dye. ICG may not be inferior to blue dye and is a useful adjunct to radioisotope in SLN biopsy in cutaneous melanoma.

Для цитирования: Fadel Michael G, Rauf Sidra, Mohamed Hesham S, Yusuf Siraj, Hayes Andrew J, Power Kieran, Smith Myles J. The Use of Indocyanine Green and Near-Infrared Fluorescence Imaging Versus Blue Dye in Sentinel Lymph Node Biopsy in Cutaneous Melanoma: A Retrospective, Cohort Study.. Annals of surgical oncology. 2023. DOI: 10.1245/s10434-023-13405-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.