Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract.

Ke Xixuan, Li Cuilian, Lin Liyu, Huang Yuqiang, Xia Honghe, Jin Chuang, Shi Tingkun, Zhang Qi, Liao Xulong, Chen Haoyu

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate the performance of 10 MHz ultrasonography in detecting posterior lens capsule defects before traumatic cataract surgery.

METHODS

This retrospective analysis includes patients with traumatic cataracts who underwent cataract surgery. Preoperative 10 MHz ultrasonography was performed to evaluate whether the posterior lens capsule was defective or intact, and the results were compared to the intraoperative findings. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa were calculated.

RESULTS

The study included 140 eyes of 140 patients. There were 68 eyes with closed-globe injuries and 72 eyes with open-globe injuries. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and kappa of 10 MHz ultrasonography was 86.76%, 90.28%, 89.39%, 87.84%, 88.57% and 0.771, respectively. The accuracy was 86.11% and 91.18% in open-globe and closed-globe injury groups, respectively.

CONCLUSION

The accuracy of 10 MHz ultrasonography in evaluating the posterior lens capsule in traumatic cataracts is high. Preoperative 10 MHz ultrasonography would help to make an appropriate surgical plan.

Для цитирования: Ke Xixuan, Li Cuilian, Lin Liyu, Huang Yuqiang, Xia Honghe, Jin Chuang, Shi Tingkun, Zhang Qi, Liao Xulong, Chen Haoyu. Accuracy of 10 MHz ultrasonography for evaluation of posterior lens capsule in traumatic cataract.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2024. DOI: 10.1007/s00417-024-06523-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.