MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.10344

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2003

Serial MR imaging with MS-325 for evaluating female sexual arousal response: determination of intrasubject reproducibility.

Maravilla Kenneth R, Cao Yunyu, Heiman Julia R, Garland Patricia A, Peterson Barry T, Carter Wayne O, Weisskoff Robert M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine if a similar sexual arousal response in normal, healthy women could be obtained and monitored by serial magnetic resonance (MR) imaging at two separate sessions.

MATERIALS AND

METHODS

Serial imaging of the external genitalia was performed on nine healthy, sexually functional women at two separate MR sessions after administration of the contrast agent, MS-325. Images were obtained every three minutes during a 45-minute study period during each MR session. The second MR session began approximately 45 minutes after the end of the first MR session. While undergoing imaging, subjects viewed videotapes that contained neutral and sexually-explicit material through an audiovisual system. Analysis performed at each time point consisted of visual evaluation of the images, clitoral and femoral vein signal intensity measurements, relative regional blood volume calculations, and clitoral volume measurements. Statistical analysis of the results consisted of calculating correlation coefficients of the two MR sessions by using the least square fit method.

RESULTS

All nine subjects reported sexual arousal on subjective questionnaires at each MR session. Post-contrast MS-325 MR images showed strong enhancement of the external genitalia at each session. There was excellent correlation between the two sessions for the clitoral volume measurements of all nine subjects. The correlation coefficient, r(2), was 0.95.

CONCLUSION

The sexual arousal response in normal, healthy women can be monitored by serial imaging combined with the use of the contrast agent, MS-325, and similar results can be reproduced at two different MR sessions. This method holds promise for future studies of women with female sexual arousal dysfunction.

Для цитирования: Maravilla Kenneth R, Cao Yunyu, Heiman Julia R, Garland Patricia A, Peterson Barry T, Carter Wayne O, Weisskoff Robert M. Serial MR imaging with MS-325 for evaluating female sexual arousal response: determination of intrasubject reproducibility.. Journal of magnetic resonance imaging : JMRI. 2003. DOI: 10.1002/jmri.10344.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.