MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.202406367

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024

An Injection Molded SlipChip with Self-Sampling for Integrated Point-of-Care Testing of Human Papilloma Virus.

Zhang Jiajie, Dong Zhangli, Xu Lei, Han Xu, Sheng Zheyi, Chen Weiyu, Zheng Jiayi, Lai Dongmei, Shen Feng

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

High-risk human papillomavirus (HPV) screening is crucial for cervical cancer prevention. However, laboratory-based nucleic acid amplification tests (NAATs) require costly equipment, designated lab space, and skilled personnel. Additionally, cervical swabs collected by healthcare professionals can be inconvenient, uncomfortable, and reduce privacy, limiting broader application and patient compliance. A SlipChip-based Integrated Point-of-Care (SIPOC) system featuring an injection-molded SlipChip is presented with preloaded reagents for nucleic acid extraction and a portable four-channel real-time quantitative PCR instrument for detection. This system incorporates a self-sampling method that allows participants to collect their own vaginal swabs, with the β-Globin gene as a control. After testing 130 participants for HPV-16 and HPV-18, 97.7% of the self-collected samples are valid. Among valid samples, 25 tested positive for HPV-16 and 9 for HPV-18. Compared to Roche's standard HPV PCR test, the SIPOC system shows 100% positive predictive value (PPV) for both HPV-16 and HPV-18 and negative predictive values (NPVs) of 99.0% and 99.1%, respectively. This system is promising for HPV screening in resource-limited settings and adaptable for other point-of-care NAAT applications, including home testing.

Для цитирования: Zhang Jiajie, Dong Zhangli, Xu Lei, Han Xu, Sheng Zheyi, Chen Weiyu, Zheng Jiayi, Lai Dongmei, Shen Feng. An Injection Molded SlipChip with Self-Sampling for Integrated Point-of-Care Testing of Human Papilloma Virus.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2024. DOI: 10.1002/advs.202406367.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.