Pediatric diabetes · 2022

Application of the FreeStyle®Libre Glucose Monitoring System in type 1 diabetes mellitus patients aged 1-4 years.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Yangshiyu, Cao Bingyan, Chen Qiong, Du Mengmeng, Yan Mingming, Chen Yongxing, Wei Haiyan, Wu Xue, Cui Yan, Liu Fang

Аннотация

BACKGROUND: To investigate the analytical accuracy, safety performance, and user satisfaction (guardians of study participants) of the FreeStyle®Libre Glucose Monitoring System in the treatment of type 1 diabetes mellitus (T1DM), in children aged <4 years.

METHODS: Sixteen hospitalized children with new onset T1DM, aged 4 months to 4 years, were enrolled in this study. Patients wore the sensor for 14 days; sensor scans were performed immediately and at 5, 10, and 15 min after capillary blood glucose (BG) measurements to evaluate the effectiveness of the device and the lag effect.

RESULTS: The consensus error grid showed that 96.40% of values fell within zone A (no clinical impact) and 3.60% within zone B (little/no clinical impact). Overall, the mean absolute relative difference (MARD) was 9.34%, and was higher in the capillary BG <4.0 mmol/L group (15.18%) than in the 4-10 mmol/L (9.63%) and >10 mmol/L (7.17%) groups. The MARD increased gradually with scanning time extension, indicating a short lag effect. Regression analysis showed that a higher BG level was associated with a greater difference in FreeStyle®Libre System measurements.

CONCLUSIONS: The use of the FreeStyle®Libre System in children aged 1-4 years is accurate and safe, and may be accurate down to 4 months, independent of patient characteristics.