Аннотация

PURPOSE: To evaluate the efficacy of three-dimensional, contrast-enhanced magnetic resonance angiography (CE-MRA) of the carotid artery with a 1.0 T system in comparison to intra-arterial conventional angiography (i.a.CA) for the assessment of carotid artery disease.

METHOD: 55 patients with suspected stenosis of the carotid artery were examined with a 3 D-CE gradient-echo sequence on a 1.0 T scanner (TR/TE = 6.2/2.2 ms) and a selective DSA i.a. angiography. Image quality was evaluated by estimating the arterial contrast and venous enhancement. Morphological pathologies were registered for all arteries, stenoses of the internal carotid artery were graded by applying the NASCET criteria.

RESULTS

Sensitivity and specificity of MRA in detecting high-grade stenosis (> or = 70%) and occlusion of the extracranial internal carotid artery were 97.7 and 94.0%. Therapeutic relevant misinterpretations were mostly based on overestimating the stenoses.

CONCLUSION

The applied CE-MRA technique with a 1.0 T system is suitable for the assessment of carotid artery stenoses. In case of a therapeutically relevant stenosis revealed by MRA, however, verification of the diagnosis by i.a. CA is recommended.

Для цитирования: Oberholzer K, Kreitner K F, Kalden P, Pitton M, Requardt M, Thelen M. [Contrast-enhanced three-dimensional MR angiography of the carotid artery at 1.0 Tesla compared to i.a. DSA: is the method suitable for the diagnosis of carotid stenosis?].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2001. DOI: 10.1055/s-2001-12476.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.