MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2131/jts.43.741

Медицинская библиотека · The Journal of toxicological sciences · 2018

The performance of an in vitro skin sensitisation test, IL-8 Luc assay (OECD442E), and the integrated approach with direct peptide reactive assay (DPRA).

Kimura Yutaka, Watanabe Mika, Suzuki Noriyuki, Iwaki Tomoko, Yamakage Kohji, Saito Koichi, Nakajima Yoshihiro, Fujimura Chizu, Ohmiya Yoshihiro, Omori Takashi, Kojima Hajime, Aiba Setsuya

СтатьяПеревод в очереди

Аннотация

In all current in vitro skin sensitisation assays, DMSO is used to dissolve water-insoluble chemicals. However, our previous study suggested the superiority of the modified IL-8 Luc assay (mIL-8 Luc), in which X-VIVOTM 15 is used to dissolve chemicals, over the original assay using DMSO (oIL-8 Luc). In this study, to confirm the superiority of the mIL-8 Luc, we first increased the number of chemicals examined and demonstrated the superiority of the mIL-8 Luc, in which the mIL-8 Luc provided 87.6% of sensitivity, 74.2% of specificity, and 84.6% of accuracy. Next, to clarify the cause of false negative judgment by the mIL-8 Luc, we examined the effects of physical properties of chemicals on judgment. The results demonstrated that high molecular weight, high LogKo/w, or poor water solubility, did not cause false negative judgment. When it was accepted as an OECD test guideline, the criteria of the mIL-8 Luc to determine sensitisers were modified to further decrease false negative judgment by poor solubility. By applying the new criteria, the test guideline IL-8 Luc assay (tgIL-8 Luc) improved sensitivity but decreased specificity and increased the number of chemicals that cannot be judged. To overcome this problem, we examined a simple combination of the tgIL-8 Luc with direct peptide reactive assay (DPRA), which could improve specificity and decrease the number of the chemicals that cannot be judged. These data suggest that the tgIL-8 Luc is a promising in vitro skin sensitisation assay in combination with other in vitro or in chemico methods.

Для цитирования: Kimura Yutaka, Watanabe Mika, Suzuki Noriyuki, Iwaki Tomoko, Yamakage Kohji, Saito Koichi, Nakajima Yoshihiro, Fujimura Chizu, Ohmiya Yoshihiro, Omori Takashi, Kojima Hajime, Aiba Setsuya. The performance of an in vitro skin sensitisation test, IL-8 Luc assay (OECD442E), and the integrated approach with direct peptide reactive assay (DPRA).. The Journal of toxicological sciences. 2018. DOI: 10.2131/jts.43.741.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.