MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joor.14024

Медицинская библиотека · Journal of oral rehabilitation · 2025

The Effect of Implant Distribution on Functional and Patient-Reported Outcomes of Mandibular Overdentures Retained by Four Mini Implants.

Ferreira de Sá Jaqueline, Nascimento Lays Noleto, de Moraes Sousa Júlia Fonseca, Curado Thalita Fernandes Fleury, Srinivasan Murali, McKenna Gerald, Schimmel Martin, Leles Cláudio Rodrigues

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: This study investigated the effects of implant distribution on functional and patient-reported outcomes of patients treated with a mandibular overdenture retained by four mini implants.

MATERIALS AND

METHODS

Seventy-four participants received four titanium-zirconium mini implants in the anterior mandible, and the relative position of the implants was assessed in post-treatment computed tomography scans with three reference points in the incisal region and first molars of the overdenture. DICOM files were analysed using Blooming Artefact Reduction filters to allow the visualisation of the mini implants in their three-dimensional position without overlapping bone structures. The implant distribution parameters were the polygon area formed by the four mini implants (implant area), anterior and posterior cantilever extensions, and antero-posterior spread. Outcomes included anterior and posterior maximum voluntary bite force (MBF), masticatory performance (MP), oral health-related quality of life impacts (OHIP-Edent) and satisfaction with the overdenture. Paired t-test, Pearson's correlation test and multiple regression were used for data analysis.

RESULTS

The implant distribution area was the most relevant variable for all functional parameters. The larger the distribution, the better the MP (p = 0.003), and the anterior (p = 0.011) and posterior MBF (p < 0.001). Concerning patient-reported outcomes, no effect of implant distribution was observed (p > 0.05), suggesting that the potential benefit of better distribution may not affect patients' perception of the treatment.

CONCLUSION

Findings corroborate the influence of implant distribution of the four mini implants on functional parameters and, although the best implant distribution may depend highly on anatomical factors, these parameters should be considered an important prognostic factor for treatment success.

TRIAL REGISTRATION: ClinicalTrials.gov: NCT04760457.

Для цитирования: Ferreira de Sá Jaqueline, Nascimento Lays Noleto, de Moraes Sousa Júlia Fonseca, Curado Thalita Fernandes Fleury, Srinivasan Murali, McKenna Gerald, Schimmel Martin, Leles Cláudio Rodrigues. The Effect of Implant Distribution on Functional and Patient-Reported Outcomes of Mandibular Overdentures Retained by Four Mini Implants.. Journal of oral rehabilitation. 2025. DOI: 10.1111/joor.14024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.