MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejrad.2025.112497

Медицинская библиотека · European journal of radiology · 2025

Accurate multi-b-value DWI generation using two-stage deep learning: multicenter study.

Xia Liang, Qi Xuan, Liu Jiayi, Yuan Yousheng, Wang Yuchun, Xu Nan, Zhang Jun

СтатьяМногоцентровое исследованиеВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study aimed to develop and validate a two-stage deep learning framework (DC2Anet-MineGAN) for high-fidelity multi-organ, multi-b-value DWI synthesis and accurate ADC restoration, addressing real-world limitations of DWI acquisition.

MATERIALS AND

METHODS

This retrospective study included DWI images collected from three hospitals (from March 2020 to March 2025) and the TCIA database, with a total of 50,000 images across five anatomical regions (brain, breast, abdomen, neck, pelvis) and b-values (0-1000 s/mm2). Images were split 8:2 into training and test sets. The two-stage model used DC2Anet for low-to-high b-value synthesis per organ and MineGAN for interpolation to arbitrary b-values. Performance was evaluated using MSE, MAE, PSNR, and SSIM, and radiologist Likert ratings with ICC for synthetic images at non-trained b-values. Group differences were assessed statistically.

RESULTS

Of 50,000 images, synthetic ADC values closely matched ground truth across all regions (mean difference < 0.02; all p > 0.05), with SSIM > 0.81 and PSNR > 74 for all b-values. For unseen b-values (b = 75, 850), 90/120 (75 %) and 60/120 (50 %) images were scored as excellent by radiologists; ICC exceeded 0.92 for both b-values. No significant difference was observed between synthetic and real ADC, and no regions showed inferior image quality. Recognizing potential hallucination or distortion, further multi-center clinical validation is required.

CONCLUSION

The proposed two-stage DC2Anet-MineGAN framework achieves accurate, high-quality DWI synthesis and ADC reproduction across multiple b-values and anatomical regions, overcoming clinical DWI limitations and supporting reliable quantitative imaging.

Для цитирования: Xia Liang, Qi Xuan, Liu Jiayi, Yuan Yousheng, Wang Yuchun, Xu Nan, Zhang Jun. Accurate multi-b-value DWI generation using two-stage deep learning: multicenter study.. European journal of radiology. 2025. DOI: 10.1016/j.ejrad.2025.112497.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.