MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11548-019-01971-9

Медицинская библиотека · International journal of computer assisted radiology and surgery · 2019

Flexible and comprehensive patient-specific mitral valve silicone models with chordae tendineae made from 3D-printable molds.

Engelhardt Sandy, Sauerzapf Simon, Preim Bernhard, Karck Matthias, Wolf Ivo, De Simone Raffaele

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Given the multitude of challenges surgeons face during mitral valve repair surgery, they should have a high confidence in handling of instruments and in the application of surgical techniques before they enter the operating room. Unfortunately, opportunities for surgical training of minimally invasive repair are very limited, leading to a situation where most surgeons undergo a steep learning curve while operating the first patients.

METHODS

In order to provide a realistic tool for surgical training, a commercial simulator was augmented by flexible patient-specific mitral valve replica. In an elaborated production pipeline, finalized after many optimization cycles, models were segmented from 3D ultrasound and then 3D-printable molds were computed automatically and printed in rigid material, the lower part being water-soluble. After silicone injection, the silicone model was dissolved from the mold and anchored in the simulator.

RESULTS

To our knowledge, our models are the first to comprise the full mitral valve apparatus, i.e., the annulus, leaflets, chordae tendineae and papillary muscles. Nine different valve molds were automatically created according to the proposed workflow (seven prolapsed valves and two valves with functional mitral insufficiency). From these mold geometries, 16 replica were manufactured. A material test revealed that EcoflexTM 00-30 is the most suitable material for leaflet-mimicking tissue out of seven mixtures. Production time was around 36 h per valve. Twelve surgeons performed various surgical techniques, e.g., annuloplasty, neo-chordae implantation, triangular leaflet resection, and assessed the realism of the valves very positively.

CONCLUSION

The standardized production process guarantees a high anatomical recapitulation of the silicone valves to the segmented models and the ultrasound data. Models are of unprecedented quality and maintain a high realism during haptic interaction with instruments and suture material.

Для цитирования: Engelhardt Sandy, Sauerzapf Simon, Preim Bernhard, Karck Matthias, Wolf Ivo, De Simone Raffaele. Flexible and comprehensive patient-specific mitral valve silicone models with chordae tendineae made from 3D-printable molds.. International journal of computer assisted radiology and surgery. 2019. DOI: 10.1007/s11548-019-01971-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.