MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3177/jnsv.68.181

Медицинская библиотека · Journal of nutritional science and vitaminology · 2022

Comparison of the Serum Total 25-Hydroxyvitamin D Concentrations Using Chemiluminescent Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry in Children.

Wang Jie, Li Xinliang, Gan Yongyi, Fan Tianxing, Yang Jing, Rao Fang, Yang Jianbo

СтатьяПеревод пока не подготовлен

Аннотация

We aimed to assess the difference and agreement between the CL-series Vitamin D Total assay (Mindray), which was a kind of chemiluminescent immunoassay (CLIA) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the measurement of serum 25-hydroxyvitamin D [25(OH)D] concentrations in children. We compared the 25(OH)D concentrations of 92 children using the CLIA and LC-MS/MS. Paired samples t-test was used to compare the two groups. Linear regression was used to show the correlation between CLIA and LC-MS/MS. The difference and bias between 2 methods were revealed in Bland-Altman plot. Agreement in classification of deficiency between CLIA and LC-MS/MS was assessed using Cohen's Kappa. p value<0.05 was considered statistically significant. Using Shapiro-Wilk Test to assess whether the data follows a normal distribution. Using 95% children's serum 25(OH)D concentrations by LC-MS/MS as the reference interval. The regression equation was CLIA=1.185×LC-MS/MS-3.328. The fitness adjusted r2 was 0.589. The CLIA showed positive bias compared to LC-MS/MS, p<0.05, bias=(1.94±16.56) ng/mL. Cohen's Kappa=0.53, p<0.001. The agreement of 2 methods in diagnosing "deficiency" was good. According to Shapiro-Wilk Test, the data followed a normal distribution (W=0.99). The reference interval of children's serum 25(OH)D concentrations by LC-MS/MS was 11.35-44.57 ng/mL. In measuring 25(OH)D concentration of children, CLIA represented higher levels than LC-MS/MS. The two methods were consistent in diagnosing vitamin D deficiency. The reference interval of children's serum 25(OH)D concentrations by LC-MS/MS was 11.35-44.57 ng/mL in our area in summer.

Для цитирования: Wang Jie, Li Xinliang, Gan Yongyi, Fan Tianxing, Yang Jing, Rao Fang, Yang Jianbo. Comparison of the Serum Total 25-Hydroxyvitamin D Concentrations Using Chemiluminescent Immunoassay and Liquid Chromatography-Tandem Mass Spectrometry in Children.. Journal of nutritional science and vitaminology. 2022. DOI: 10.3177/jnsv.68.181.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.