Direct X-ray radiogrammetry versus dual-energy X-ray absorptiometry: assessment of bone density in children treated for acute lymphoblastic leukaemia and growth hormone deficiency.

van Rijn Rick R, Boot Annemieke, Wittenberg Rianne, van der Sluis Inge M, van den Heuvel-Eibrink Marry M, Lequin Maarten H, de MuinckKeizer-Schrama Sabine M P F, Van Kuijk Cornelis

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In recent years interest in bone densitometry in children has increased.

OBJECTIVE

To evaluate the clinical application of digital X-ray radiogrammetry (DXR) and compare the results with those of dual-energy X-ray absorptiometry (DXA).

MATERIALS AND

METHODS

A total of 41 children with acute lymphoblastic leukaemia (ALL) and 26 children with growth hormone deficiency (GHD) were included in this longitudinal study. Radiographs of the left hand were obtained and used for DXR. DXA of the total body and of the lumbar spine was performed.

RESULTS

In both study populations significant correlations between DXR and DXA were found, and, with the exception of the correlation between DXR bone mineral density (DXR-BMD) and bone mineral apparent density in the GHD population, all correlations had a P-value of <0.001. During treatment a change in DXR-BMD was found in children with GHD.

CONCLUSIONS

Our study showed that DXR in a paediatric population shows a strong correlation with DXA of the lumbar spine and total body and that it is able to detect a change in BMD during treatment.

Для цитирования: van Rijn Rick R, Boot Annemieke, Wittenberg Rianne, van der Sluis Inge M, van den Heuvel-Eibrink Marry M, Lequin Maarten H, de MuinckKeizer-Schrama Sabine M P F, Van Kuijk Cornelis. Direct X-ray radiogrammetry versus dual-energy X-ray absorptiometry: assessment of bone density in children treated for acute lymphoblastic leukaemia and growth hormone deficiency.. Pediatric radiology. 2006. DOI: 10.1007/s00247-005-0080-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.