The journal of trauma and acute care surgery · 2022
Ex vivo normothermic preservation of amputated limbs with a hemoglobin-based oxygen carrier perfusate.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Figueroa Brian A, Said Sayf A, Ordenana Carlos, Rezaei Majid, Orfahli Lynn M, Dubé Gregory P, Papay Francis, Brunengraber Henri, Dasarathy Srinivasan, Rampazzo Antonio, Gharb Bahar Bassiri
Аннотация
BACKGROUND: Ex vivo normothermic limb perfusion (EVNLP) preserves amputated limbs under near-physiologic conditions. Perfusates containing red blood cells (RBCs) have shown to improve outcomes during ex vivo normothermic organ perfusion, when compared with acellular perfusates. To avoid limitations associated with the use of blood-based products, we evaluated the feasibility of EVNLP using a polymerized hemoglobin-based oxygen carrier-201 (HBOC-201).
METHODS: Twenty-four porcine forelimbs were procured from Yorkshire pigs. Six forelimbs underwent EVNLP with an HBOC-201-based perfusate, six with an RBC-based perfusate, and 12 served as static cold storage (SCS) controls. Ex vivo normothermic limb perfusion was terminated in the presence of systolic arterial pressure of 115 mm Hg or greater, fullness of compartments, or drop of tissue oxygen saturation by 20%. Limb contractility, weight change, compartment pressure, tissue oxygen saturation, oxygen uptake rates (OURs) were assessed. Perfusate fluid-dynamics, gases, electrolytes, metabolites, methemoglobin, creatine kinase, and myoglobin concentration were measured. Uniformity of skin perfusion was assessed with indocyanine green angiography and infrared thermography.
RESULTS: Warm ischemia time before EVNLP was 35.50 ± 8.62 minutes (HBOC-201), 30.17 ± 8.03 minutes (RBC) and 37.82 ± 10.45 (SCS) (p = 0.09). Ex vivo normothermic limb perfusion duration was 22.5 ± 1.7 hours (HBOC-201) and 28.2 ± 7.3 hours (RBC) (p = 0.04). Vascular flow (325 ± 25 mL·min-1 vs. 444.7 ± 50.6 mL·min-1; p = 0.39), OUR (2.0 ± 1.45 mL O2·min-1·g-1 vs. 1.3 ± 0.92 mL O2·min-1·g-1 of tissue; p = 0.80), lactate (14.66 ± 4.26 mmol·L-1 vs. 13.11 ± 6.68 mmol·L-1; p = 0.32), perfusate pH (7.53 ± 0.25 HBOC-201; 7.50 ± 0.23 RBC; p = 0.82), flexor (28.3 ± 22.0 vs. 27.5 ± 10.6; p = 0.99), and extensor (31.5 ± 22.9 vs. 28.8 ± 14.5; p = 0.82) compartment pressures, and weight changes (23.1 ± 3.0% vs. 13.2 ± 22.7; p = 0.07) were not significantly different between HBOC-201 and RBC groups, respectively. In HBOC-201 perfused limbs, methemoglobin levels increased, reaching 47.8 ± 12.1% at endpoint. Methemoglobin saturation did not affect OUR (ρ = -0.15, r2 = 0.022; p = 0.45). A significantly greater number of necrotic myocytes was found in the SCS group at endpoint (SCS, 127 ± 17 cells; HBOC-201, 72 ± 30 cells; RBC-based, 56 ± 40 cells; vs. p = 0.003).
CONCLUSION: HBOC-201- and RBC-based perfusates similarly support isolated limb physiology, metabolism, and function.
METHODS: Twenty-four porcine forelimbs were procured from Yorkshire pigs. Six forelimbs underwent EVNLP with an HBOC-201-based perfusate, six with an RBC-based perfusate, and 12 served as static cold storage (SCS) controls. Ex vivo normothermic limb perfusion was terminated in the presence of systolic arterial pressure of 115 mm Hg or greater, fullness of compartments, or drop of tissue oxygen saturation by 20%. Limb contractility, weight change, compartment pressure, tissue oxygen saturation, oxygen uptake rates (OURs) were assessed. Perfusate fluid-dynamics, gases, electrolytes, metabolites, methemoglobin, creatine kinase, and myoglobin concentration were measured. Uniformity of skin perfusion was assessed with indocyanine green angiography and infrared thermography.
RESULTS: Warm ischemia time before EVNLP was 35.50 ± 8.62 minutes (HBOC-201), 30.17 ± 8.03 minutes (RBC) and 37.82 ± 10.45 (SCS) (p = 0.09). Ex vivo normothermic limb perfusion duration was 22.5 ± 1.7 hours (HBOC-201) and 28.2 ± 7.3 hours (RBC) (p = 0.04). Vascular flow (325 ± 25 mL·min-1 vs. 444.7 ± 50.6 mL·min-1; p = 0.39), OUR (2.0 ± 1.45 mL O2·min-1·g-1 vs. 1.3 ± 0.92 mL O2·min-1·g-1 of tissue; p = 0.80), lactate (14.66 ± 4.26 mmol·L-1 vs. 13.11 ± 6.68 mmol·L-1; p = 0.32), perfusate pH (7.53 ± 0.25 HBOC-201; 7.50 ± 0.23 RBC; p = 0.82), flexor (28.3 ± 22.0 vs. 27.5 ± 10.6; p = 0.99), and extensor (31.5 ± 22.9 vs. 28.8 ± 14.5; p = 0.82) compartment pressures, and weight changes (23.1 ± 3.0% vs. 13.2 ± 22.7; p = 0.07) were not significantly different between HBOC-201 and RBC groups, respectively. In HBOC-201 perfused limbs, methemoglobin levels increased, reaching 47.8 ± 12.1% at endpoint. Methemoglobin saturation did not affect OUR (ρ = -0.15, r2 = 0.022; p = 0.45). A significantly greater number of necrotic myocytes was found in the SCS group at endpoint (SCS, 127 ± 17 cells; HBOC-201, 72 ± 30 cells; RBC-based, 56 ± 40 cells; vs. p = 0.003).