MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1123/jab.2020-0327

Медицинская библиотека · Journal of applied biomechanics · 2021

Clinical Walking Tests and Gait Pattern Characterization During 6-Minute Walk Test Using Inertial Sensors: Follow-Up in Individuals With Lower Limb Amputation.

Younesian Hananeh, Legrand Thomas, Miramand Ludovic, Beausoleil Sarah, Turcot Katia

СтатьяПеревод пока не подготовлен

Аннотация

Inertial measurement units and normative values enable clinicians to quantify clinical walking tests and set rehabilitation goals. Objectives of this study were (1) to compare time- and distance-based walking tests in individuals with lower limb amputation (iLLA) and normative values following rehabilitation discharge (T1) and 6 weeks after discharge (T2) and (2) to investigate spatiotemporal and foot kinematic parameters over a 6-minute walk test using inertial measurement units. Twelve iLLA participated in this study. Distance, cadence, stance ratio, loading rate ratio, push-up ratio, path length, and minimum toe clearance were analyzed during 6-minute walk test. Nonparametric repeated-measures analysis of variance tests, Bonferroni corrections, were performed. Time of distance-based walking tests diminished at T2 (P < .02). Compared with normative values, walking performance in iLLA was reduced. Cadence at T2 increased significantly (P = .026). Stance ratio increased in both legs at T2 (P < .05). Push-up ratio tended to decrease at T2 in the amputated leg (P = .0003). Variability of path length and minimum toe clearance at T2 were less than at T1 in the nonamputated leg (P < .05). Spatiotemporal improvement at T2 could be due to prosthesis adaptation in iLLA. The lower performance of the functional walk test compared with normative values could be due to amputation and pain-related fatigue.

Для цитирования: Younesian Hananeh, Legrand Thomas, Miramand Ludovic, Beausoleil Sarah, Turcot Katia. Clinical Walking Tests and Gait Pattern Characterization During 6-Minute Walk Test Using Inertial Sensors: Follow-Up in Individuals With Lower Limb Amputation.. Journal of applied biomechanics. 2021. DOI: 10.1123/jab.2020-0327.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.