MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejmp.2019.03.020

Медицинская библиотека · Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2019

Organ and effective doses detriment to paediatric patients undergoing multiple interventional cardiology procedures.

Ubeda Carlos, Vano Eliseo, Miranda Patricia, Figueroa Ximena

СтатьяПеревод пока не подготовлен

Аннотация

The aims of the present study were to present the frequency of multiple interventional cardiac procedures for a certain group of patients obtained at one of the largest paediatric hospitals in Chile. In addition it has been analysed cumulative kerma area product (KAP) and cumulative air kerma (CAK), and calculated organ doses for the patient groups undergoing 2, 3 and ≥ 4 procedures, using Monte Carlo software. Effective doses were also estimated for epidemiological purposes and to permit comparison with other imaging procedures. The sample used corresponds to the last 9 years and refers to a total of 1521 paediatric patients and 1824 interventional cardiac procedures. The results for frequency were: 13.7% of patients underwent 2 procedures, 4.1% underwent 3 procedures and 1.4% underwent 4 or more procedures. The median KAP and CAK values measured for the cumulative procedures in these three groups of patients were 3.7, 5.4 and 10.8 Gy·cm2 and 59.9, 83.2 and 147.6 mGy, respectively. In terms of the most irradiated organs during interventional cardiac procedures, the highest median values (for the group of ≥4 procedures) were: active bone marrow 5.0 mGy, lungs 23.5 mGy, oesophagus 15.2 mGy, thyroid 7.8 mGy and breast 11.0 mGy. Median dose value to the heart (for the group of ≥4 procedures) was 12.7 mGy. Median values in terms of calculated effective dose for the three patient groups (with 2, 3 and ≥4 procedures) were 3.4, 5.9 and 8.7 mSv, respectively.

Для цитирования: Ubeda Carlos, Vano Eliseo, Miranda Patricia, Figueroa Ximena. Organ and effective doses detriment to paediatric patients undergoing multiple interventional cardiology procedures.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2019. DOI: 10.1016/j.ejmp.2019.03.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.